English
Language : 

CPK600PS24 Datasheet, PDF (3/4 Pages) XP Power Limited – AC-DC Chassis Mount
Mechanical Details 1000 Watts
NOTE: ‘-F’ option (24 V models only) increases the overall height from 75 to 106 mm.
Weight 2.5 kg
SYMBOL
VB
CB
+V
+V
-V
-V
FG
N
L
PIN CONNECTIONS
FUNCTION
Voltage Balance
Current Balance
Output Terminal (+)
Output Terminal (+)
Output Terminal (-)
Output Terminal (-)
Frame Ground
AC (N)
AC(L)
Average 21 A max per pin for TB1
SCREW
M3
M4
OPTIONAL CN3 PIN CONNECTIONS
PIN
FUNCTION
SYMBOL
1
ROF + (-R)
RC+
2
ROF - (-R)
RC-
3-8
N/C
NC
9
LV Alarm (-W)
LV+
10
LV Alarm Ground (-W)
LV-
11-12
N/C
NC
13
PF Alarm + (-W)
PF+
14
PF Alarm Ground (-W)
PF-
Connector Mating Connector
Terminal
Chain: SPHD-002T-P.0.5
CN3 S148B-PHDSS PHDR-14VS Loose: BPHD-001T-P0.5
BPHD-002T-P0.5
Mfr
J.S.T
For mating loom kit for optional CN3 order
part number “CPK CN3 LOOM”
Forced Air Cooling (60 CFM)
The temperature points A and B shown are marked
on the psu chassis.
• Point A must be ≤ 60°C and point B must be
≤65°C at Ta = 50°C.
• Point A must be ≤ 80°C and point B must be ≤
80°C at Ta = 70°C.
The confirmation of the temperatures of point A and
B is not necessary if option fan “-F” is used.
Convection Cooled - Derating Curves
Convection Cooled
CPK 750
Load factor is dependent on input
voltage and is an average power figure.
(See part number table).
Installation Method
Note: 1. Output ripple & noise may be outside specification.
2. Load factor dependent on input voltage (see part number table) and is an average power figure.
CPK 600
CPK 1000
www.xpplc.com
sales@xpplc.com