CPK600PS24 Datasheet, PDF (1/4 Pages) XP Power Limited – AC-DC Chassis Mount | |||
|
AC-DC Chassis Mount
600-1000 Watts
CPK Series
THE XPERTS IN POWER
Specification
Input
Input Voltage
â¢
Input Frequency
â¢
Inrush Current
â¢
Power Factor
â¢
Earth Leakage Current â¢
Output
Output Voltage
â¢
Output Voltage
â¢
Adjustment
Minimum Load
â¢
Start Up time
â¢
Hold Up time
â¢
Initial Set Accuracy â¢
Drift
â¢
Line Regulation
â¢
Load Regulation
â¢
Ripple & Noise
â¢
Overvoltage
â¢
Protection
Overcurrent
â¢
Protection
Remote ON/OFF
â¢
(Optional)
General
Efficiency
â¢
Isolation
â¢
85-264 VAC (120-350 VDC)
47-63 Hz
20/40 A typical at 115/230 VAC
0.98 typical at 230 VAC at 100% load
0.75 mA max at 230 VAC 60Hz
for 0.50 mA add suffix â-Eâ,
for 0.15 mA add suffix â-Gâ
See Table
See Table
No minimum load required
500 ms max at 100 VAC 100% load
20 ms typical at 100 VAC 100% load
±1% max
±0.4%
±0.4% from low line to high line
±0.7% max from 0-100% load
±0.8% max pk-pk 20 MHz bandwidth
115-140% of Vnom, recycle input to
restart
101% of peak current auto recovery
Add suffix â-Râ to model number
ON 4.5-12.5 V (open circuit)
between RC+ and RC-
OFF 0 to 0.5 V (short circuit)
between RC+ and RC-
86-89% dependent on model
3000 VAC Input to Output
2000 VAC Input to Ground
â¢
â¢
Up to 2 kW Peak Rating
â¢
Wide Output Voltage Adjustment
â¢
Up to 500 W Convection Cooled
â¢
Optional Conformal Coating
â¢
Optional Remote ON/OFF
â¢
Optional AC, DC & Fan Fail Signals
Switching
Frequency
⢠85 kHz ±15% active PFC
130 kHz ±15% forward converter
Vertical
Terminal block
⢠Add suffix â-Tâ to model numbers
Din Rail Mounting ⢠Add suffix â-NIâ to model numbers
Fan Fitted
⢠Add suffix â-Fâ to model number
(only available on 24 V units)
N+1 Operation
⢠Option â-Wâ & external oring diodes
Alarms (Optional)
⢠For AC fail, DC fail and fan fail add
suffix â-Wâ to model number
Conformal Coating ⢠Add suffix â-Lâ to model numbers
Environmental
Operating
â¢
Temperature
Storage Temperature â¢
Relative Humidity â¢
Shock
â¢
Vibration
â¢
-10 °C to +70 °C (fan cooled)
Derate linearly above +50 °C to 60%
load at +70 °C.
For convection cooled rating - See
Derating Curves
-20 °C to +75 °C
20-90% RH non-condensing
20 G, 11 ms once each, X, Y & Z axis
2 G, 3 min period, 60 min each along
X, Y & Z axis
EMC & Safety
Emissions
â¢
ESD Susceptibility â¢
Radiated
â¢
Susceptibility
EFT/Burst
â¢
Surge
â¢
Safety Approvals
â¢
EN55022 level B conducted
(level A with option E not available with
option G) EN55022 level B radiated
EN61000-4-2 Level 2 contact Level 3 air
EN61000-4-3 Level 3
EN61000-4-4 Level 4
EN61000-4-5 Level 3 line to line
Level 4 line to ground
UL60950, C-UL (CSA60950),
EN60950, EN50178
â¢
www.xpplc.com
sales@xpplc.com
|
▷ |