Specification
Input
Input Voltage
•
Input Frequency
•
Inrush Current
•
Power Factor
•
Earth Leakage Current •
Output
Output Voltage
•
Output Voltage
•
Adjustment
Minimum Load
•
Start Up time
•
Hold Up time
•
Initial Set Accuracy •
Drift
•
Line Regulation
•
Load Regulation
•
Ripple & Noise
•
Overvoltage
•
Protection
Overcurrent
•
Protection
Remote ON/OFF
•
(Optional)
General
Efficiency
•
Isolation
•
85-264 VAC (120-350 VDC)
47-63 Hz
20/40 A typical at 115/230 VAC
0.98 typical at 230 VAC at 100% load
0.75 mA max at 230 VAC 60Hz
for 0.50 mA add suffix ‘-E’,
for 0.15 mA add suffix ‘-G’
See Table
See Table
No minimum load required
500 ms max at 100 VAC 100% load
20 ms typical at 100 VAC 100% load
±1% max
±0.4%
±0.4% from low line to high line
±0.7% max from 0-100% load
±0.8% max pk-pk 20 MHz bandwidth
115-140% of Vnom, recycle input to
restart
101% of peak current auto recovery
Add suffix ‘-R’ to model number
ON 4.5-12.5 V (open circuit)
between RC+ and RC-
OFF 0 to 0.5 V (short circuit)
between RC+ and RC-
86-89% dependent on model
3000 VAC Input to Output
2000 VAC Input to Ground
•
•
Up to 2 kW Peak Rating
•
Wide Output Voltage Adjustment
•
Up to 500 W Convection Cooled
•
Optional Conformal Coating
•
Optional Remote ON/OFF
•
Optional AC, DC & Fan Fail Signals
Switching
Frequency
• 85 kHz ±15% active PFC
130 kHz ±15% forward converter
Vertical
Terminal block
• Add suffix ‘-T’ to model numbers
Din Rail Mounting • Add suffix ‘-NI’ to model numbers
Fan Fitted
• Add suffix ‘-F’ to model number
(only available on 24 V units)
N+1 Operation
• Option ‘-W’ & external oring diodes
Alarms (Optional)
• For AC fail, DC fail and fan fail add
suffix ‘-W’ to model number
Conformal Coating • Add suffix ‘-L’ to model numbers
Environmental
Operating
•
Temperature
Storage Temperature •
Relative Humidity •
Shock
•
Vibration
•
-10 °C to +70 °C (fan cooled)
Derate linearly above +50 °C to 60%
load at +70 °C.
For convection cooled rating - See
Derating Curves
-20 °C to +75 °C
20-90% RH non-condensing
20 G, 11 ms once each, X, Y & Z axis
2 G, 3 min period, 60 min each along
X, Y & Z axis
EMC & Safety
Emissions
•
ESD Susceptibility •
Radiated
•
Susceptibility
EFT/Burst
•
Surge
•
Safety Approvals
•
EN55022 level B conducted
(level A with option E not available with
option G) EN55022 level B radiated
EN61000-4-2 Level 2 contact Level 3 air
EN61000-4-3 Level 3
EN61000-4-4 Level 4
EN61000-4-5 Level 3 line to line
Level 4 line to ground
UL60950, C-UL (CSA60950),
EN60950, EN50178
•
www.xpplc.com