Models and Ratings
Input
Voltage
Current
Max
Peak
3.3 V (2.64 - 3.96)
300 A
-
5.0 V (3.96 - 6.00)
300 A
-
7.5 V (5.25 - 8.25)
200 A
-
12 V (8.25 - 13.20)
125 A
-
15 V (10.50 - 16.50)
100 A
-
24 V (16.50 - 26.40)
70 A (1)
105 A (2)
36 V (25.20 - 39.60)
47 A (1)
70 A (2)
48 V (38.40 - 56.00)
35 A (1)
-
Regulation
Line
Load
20 mV
40 mV
20 mV
40 mV
36 mV
60 mV
48 mV
100 mV
60 mV
120 mV
96 mV
150 mV
114 mV
150 mV
192 mV
300 mV
CPB1K5
Ripple & Noise(3) Efficiency(4)
120 mV
120 mV
150 mV
150 mV
150 mV
150 mV
200 mV
200 mV
75%
81%
81%
82%
86%
86%
86%
86%
Model
Number(3)
CPB1K5PS3V3
CPB1K5PS05
CPB1K5PS7V5
CPB1K5PS12
CPB1K5PS15
CPB1K5PS24
CPB1K5PS36
CPB1K5PS48
Notes
1. At low input voltage i.e. 115 V nom derate to 65 A, 42 A and 32 A.
2. Peak current duration 10 s max with duty cycle ≤ 35% 170-264 VAC only.
3. Measured over a 20 MHz bandwidth from 0 ºC to +50 ºC.
4. Measured at nominal 230 VAC input and 100% load.
Mechanical Details
15.85
Name plate
M4
Input terminal cover
25max
AC(L)
AC(N)
NC
FG( )
CN1
CN2
CN3
Notes:
1. Tolerance: ±1.
2. Weight: 3.4 Kg.
3. Dimensions in mm.
51.25
Output voltage
adjustable potentiometer
LED
Output terminal(-)
Output terminal(+)
19
(45)
4-M4
2-º 9
171.5 ±0.5
268
8-M4
Mounting Hole
(Both sides)
6max
8-M4
Mounting Hole
(Both sides)
AIR FLOW
CN1/CN2 PIN CONNECTIONS
Pin
Function
1 +M + Output Voltage Monitoring
2 +S + Remote Sensing
3 -M - Output Voltage Monitoring
4 -S - Remote Sensing
5 VB Voltage Balance
6 CB Current Balance
7 TRM Adjustment of Output Voltage
8 -S - Remote Sensing
9 RC2 Remote On/Off
10 RCG Remote On/Off Ground
CN3 PIN CONNECTIONS
Pin
Function
1 -S - Remote Sensing
2 -S - Remote Sensing
3 AUX Auxiliary Output (12V/0.1A)
4 RC1 Remote On/Off
5 AUXG AUX Ground
6 N.C No Connection
7 PG Power Good Signal
8 PGG Power Good Ground
10 15
19
171.5 ±0.5
Output Voltage Adjustment
60-110% of the rated output voltage is achieved by:
1. Using on-board potentiometer
2. Applying a voltage externally between
TRM & -S on CN1 or CN2
3. Connecting a resistor externally between
TRM & -S on CN1 or CN2
The external voltage level is calculated below and
should not be less than -0.7 V or more than 3.0 V.
External Trim Voltage =
Required Vout x 2.5
Vnom
Peak Current Conditions:
• 170-264 VAC
• t1 ≤ 10 s
• lp ≤ Rated peak current
• lave ≤ Rated current
• Duty =
t1
t1 + t2
x 100 [%] ≤ 35%
Peak Current
lp
(Peak Current)
lave
(Average Current)
CN1
CN2
CN3
Connector
S10B-PHDSS
S8B-PHDSS
t1
Mating Connector & Terminal - CN1, CN2 & CN3
Mating Connector
Terminal
PHDR-10VS
PHDR-8VS
Reel SPHD-002T-P0.5
Loose BPHD-001T-P0.5
BPHD-002T-P0.5
t2
Manufacturer
J.S.T
04 AUG 05