English
Language : 

ECC Datasheet, PDF (1/2 Pages) XP Power Limited – 100 W - Baseplate Cooled
100 Watts
ECC Series
xppower.com
• 40 °C to +75 °C Operation
• 100 W Baseplate Cooled
• High Efficiency Resonant Topology
• Screw Terminals Available
• 5V Standby Output
• Remote On/Off & Power OK Signal
• 3 Year Warranty
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage Current
Input Protection
• 85-264 VAC (120-370 VDC), derate output
power <90 VAC by 10%
• 47-400 Hz(1)
• 1.5 A typical at 115 VAC, full load
0.9 A typical at 230 VAC, full load
• 40 A max at 230 VAC, 25 °C cold start
• EN61000-3-2, class A
• 300 µA at 264 VAC/60 Hz max
110/190 µA 115/230 VAC at 50 Hz and
0.5/1.1 mA 115/230 VAC at 400 Hz typ.
• Internal T5.0 A/250 V fuse in line
and neutral
Output
Output Voltage
• 12-48 VDC (see tables)
Output Voltage Trim • ±5%
Initial Set Accuracy • ±1% V1, ±3% V2
Minimum Load
• No minimum load required
Start Up Delay
• Typically 1 s(2)
Start Up Rise Time
• 50 ms typical
Hold Up Time
• 16 ms min at 115 VAC
Drift
• ±0.2% after 20 min warm up
Line Regulation
• ±0.5% max
Load Regulation
• ±1% V1, ±5% V2 max
Over/Undershoot
• 5% typical
Transient Response
• 4% max. deviation, recovery to within
1% in 500 µs for a 50-75-50% load
change
Ripple & Noise
• 1% pk-pk V1, V2 2%, 20 MHz bandwidth
Overvoltage Protection • 115-140% Vnom, recycle input to reset
Overload Protection
• 110-150% V1 only (see longform
datasheet for further details)
Short Circuit Protection • Continuous trip and restart (hiccup mode)
Temperature
Coefficient
• 0.05%/°C
Remote Sense
• Compensates for 0.5 V total voltage drop
Remote On/Off
• Uncommitted isolated optocoupler diode,
powered diode inhibits V1
Notes
1. Safety approvals cover frequency 47-63 Hz.
2. At low temperature and low line voltage, start up time will increase.
General
Efficiency
Isolation
Switching Frequency
Signals
Power Density
MTBF
• 88% typical
• 4000 VAC Input to Output,
1500 VAC Input to Ground,
500 VDC Output to Ground
• 70 kHz typical
• Power OK - open collector,
Remote On/Off, 5 V Standby (see longform
datasheet for further details)
• 3.91 W/in3
• 236 kHrs to MIL-HDBK-217F at 25 °C, GB
Environmental
Operating Temperature • -40 °C to +75 °C ambient. Baseplate must
be maintained ≤+85 °C, see longform
datasheet for further details
Warm Up Time
• Typically 20 minutes
Cooling
• Baseplate, conduction cooling
Operating Humidity • 95% RH, non-condensing
Storage Temperature • -40 ˚C to +85 °C
Operating Altitude
• 3000 m
Shock
• 30 g pk, half sine, 6 axes
Vibration
• 2 g rms, 5 Hz to 500 Hz, 3 axes
EMC & Safety
Low Voltage PSU EMC • EN61204-3, high severity level as below
Emissions
• EN55022 level B conducted
EN55022 level A radiated
Harmonic Currents
• EN61000-3-2, class A
Voltage Flicker
• EN61000-3-3
Radiated Immunity
• EN61000-4-3, level 3 Perf Criteria A
EFT/Burst
• EN61000-4-4, level 3 Perf Criteria A
Surge
• EN61000-4-5, installation class 3
Perf Criteria A, installation class 4
Perf Criteria A with optional filter board (-F),
see longform datasheet for further details
Conducted Immunity • EN61000-4-6, level 3 Perf Criteria A
Dips & Interruptions
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
Safety Approvals
• IEC60950-1 CB report, CSA 22.2 No.
60950-1, UL60950-1, TUV EN60950-1
Equipment Protection • Class I
Class