ECC Datasheet, PDF (1/2 Pages) XP Power Limited – 100 W - Baseplate Cooled | |||
|
100 Watts
ECC Series
xppower.com
⢠40 °C to +75 °C Operation
⢠100 W Baseplate Cooled
⢠High Efficiency Resonant Topology
⢠Screw Terminals Available
⢠5V Standby Output
⢠Remote On/Off & Power OK Signal
⢠3 Year Warranty
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage Current
Input Protection
⢠85-264 VAC (120-370 VDC), derate output
power <90 VAC by 10%
⢠47-400 Hz(1)
⢠1.5 A typical at 115 VAC, full load
0.9 A typical at 230 VAC, full load
⢠40 A max at 230 VAC, 25 °C cold start
⢠EN61000-3-2, class A
⢠300 µA at 264 VAC/60 Hz max
110/190 µA 115/230 VAC at 50 Hz and
0.5/1.1 mA 115/230 VAC at 400 Hz typ.
⢠Internal T5.0 A/250 V fuse in line
and neutral
Output
Output Voltage
⢠12-48 VDC (see tables)
Output Voltage Trim ⢠±5%
Initial Set Accuracy ⢠±1% V1, ±3% V2
Minimum Load
⢠No minimum load required
Start Up Delay
⢠Typically 1 s(2)
Start Up Rise Time
⢠50 ms typical
Hold Up Time
⢠16 ms min at 115 VAC
Drift
⢠±0.2% after 20 min warm up
Line Regulation
⢠±0.5% max
Load Regulation
⢠±1% V1, ±5% V2 max
Over/Undershoot
⢠5% typical
Transient Response
⢠4% max. deviation, recovery to within
1% in 500 µs for a 50-75-50% load
change
Ripple & Noise
⢠1% pk-pk V1, V2 2%, 20 MHz bandwidth
Overvoltage Protection ⢠115-140% Vnom, recycle input to reset
Overload Protection
⢠110-150% V1 only (see longform
datasheet for further details)
Short Circuit Protection ⢠Continuous trip and restart (hiccup mode)
Temperature
Coefficient
⢠0.05%/°C
Remote Sense
⢠Compensates for 0.5 V total voltage drop
Remote On/Off
⢠Uncommitted isolated optocoupler diode,
powered diode inhibits V1
Notes
1. Safety approvals cover frequency 47-63 Hz.
2. At low temperature and low line voltage, start up time will increase.
General
Efficiency
Isolation
Switching Frequency
Signals
Power Density
MTBF
⢠88% typical
⢠4000 VAC Input to Output,
1500 VAC Input to Ground,
500 VDC Output to Ground
⢠70 kHz typical
⢠Power OK - open collector,
Remote On/Off, 5 V Standby (see longform
datasheet for further details)
⢠3.91 W/in3
⢠236 kHrs to MIL-HDBK-217F at 25 °C, GB
Environmental
Operating Temperature ⢠-40 °C to +75 °C ambient. Baseplate must
be maintained â¤+85 °C, see longform
datasheet for further details
Warm Up Time
⢠Typically 20 minutes
Cooling
⢠Baseplate, conduction cooling
Operating Humidity ⢠95% RH, non-condensing
Storage Temperature ⢠-40 ËC to +85 °C
Operating Altitude
⢠3000 m
Shock
⢠30 g pk, half sine, 6 axes
Vibration
⢠2 g rms, 5 Hz to 500 Hz, 3 axes
EMC & Safety
Low Voltage PSU EMC ⢠EN61204-3, high severity level as below
Emissions
⢠EN55022 level B conducted
EN55022 level A radiated
Harmonic Currents
⢠EN61000-3-2, class A
Voltage Flicker
⢠EN61000-3-3
Radiated Immunity
⢠EN61000-4-3, level 3 Perf Criteria A
EFT/Burst
⢠EN61000-4-4, level 3 Perf Criteria A
Surge
⢠EN61000-4-5, installation class 3
Perf Criteria A, installation class 4
Perf Criteria A with optional filter board (-F),
see longform datasheet for further details
Conducted Immunity ⢠EN61000-4-6, level 3 Perf Criteria A
Dips & Interruptions
⢠EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
Safety Approvals
⢠IEC60950-1 CB report, CSA 22.2 No.
60950-1, UL60950-1, TUV EN60950-1
Equipment Protection ⢠Class I
Class
|
▷ |