BCC200PS03 Datasheet, PDF (1/2 Pages) XP Power Limited – AC-DC Power Supplies | |||
|
200-400 Watts
BCC Series
xppower.com
⢠Baseplate-cooled
⢠Wide Operating Temperature Range
⢠ETSI, EMC and Environmental Compliant
⢠Parallel Operation
⢠Active PFC
⢠Remote On/Off
⢠Low Temperature Option
Specification
Input
Input Voltage
⢠90-264 VAC
Input Frequency
⢠47-63 Hz
Input Current
⢠3 A max at 90 VAC (BCC200)
6 A max at 90 VAC (BCC400)
Inrush Current
⢠60 A at 264 VAC +25 ºC cold start
Power Factor
⢠>0.9
Earth Leakage Current ⢠<1.5 mA at 230 VAC
Input Protection
⢠Internal 10 A fuse
Output
Output Power
⢠See table
Output Voltage
⢠See table
Output Voltage Trim ⢠60% to 110% Vnom
Initial Set Accuracy ⢠±1% nominal
Minimum Load
⢠No minimum load
Hold Up Time
⢠10 ms min
Line Regulation
⢠±0.5%
Load Regulation
⢠See table
Ripple & Noise
⢠<1% pk-pk, 20 MHz bandwidth
Overvoltage Protection ⢠105-140% Vnom
(3.3 V version 130-166%)
Overtemperature
Protection
⢠Shuts down at +115 ºC baseplate
temperature with auto recovery
Overload Protection
⢠102-140% constant current limiting with
auto recovery
Temperature
Coefficient
⢠0.05%/ºC
Remote Sense
⢠Compensates for lead drops of up to
500 mV
Remote On/Off
Current Share
⢠A logic â0â on the Remote On/Off
connection electronically disables
the output
⢠Up to 3 power supplies can be connected
in parallel sharing within 10%, total output
power derates by 10%
General
Efficiency
Isolation
Switching Frequency
MTBF
⢠80% typical
⢠3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
⢠PWM 360 kHz typ, PFC 90 kHz typ
⢠160 kHrs per MIL-HDBK-217F at 25 ºC
Environmental
Operating Temperature ⢠-20 ºC to +70 ºC, with baseplate
maintained below +83 ºC utilizing system
cooling, -40 ºC option available - add
suffix âLâ to model number
Cooling
⢠Conduction via 6mm baseplate
Operating Humidity
⢠20-95% RH, non-condensing. Units can
be conformally coated for high humidity
environments - add suffix âEâ
Storage Temperature ⢠-40 ºC to +85 ºC
Shock & Vibration
⢠2 g 10 min/1 cycle, 10 Hz to 500 kHz,
60 mins each axis
EMC & Safety
Emissions
Harmonic Currents
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
⢠EN55022, level B conducted &
level A radiated
⢠EN61000-3-2, EN61000-3-3
⢠EN61000-4-2, level 3 Perf Criteria A
⢠EN61000-4-3, 3 V/m Perf Criteria A
⢠EN61000-4-4, level 3 Perf Criteria A
⢠EN61000-4-5, level 3 Perf Criteria A
⢠EN61000-4-6, level 3 Perf Criteria A
⢠EN61000-4-11, 30% 10 ms,
60% 100 ms, 100% 5000 ms,
Perf Criteria A, B, B
⢠UL60950-1:2003,
CSA22.2 No. 60950-1-03, CE Mark LVD
EN60950-1:2001
|
▷ |