English
Language : 

X88064 Datasheet, PDF (9/15 Pages) Xicor Inc. – E2 Micro-Peripheral
X88064
ABSOLUTE MAXIMUM RATINGS*
Temperature under Bias.......................–65°C to +135°C
Storage Temperature ...........................–65°C to +150°C
Voltage on any Pin with
Respect to VSS .......................................... –1V to +7V
D.C. Output Current.................................................5 mA
Lead Temperature
(Soldering, 10 seconds)300°C
RECOMMENDED OPERATING CONDITIONS
*COMMENT
Stresses above those listed under “Absolute Maximum Rat-
ings” may cause permanent damage to the device. This is a
stress rating only and the functional operation of the device
at these or any other conditions above those indicated in the
operational sections of this specification is not implied. Ex-
posure to absolute maximum rating conditions for extended
periods may affect device reliability.
Temperature
Commercial
Industrial
Min.
0°C
–40°C
Max.
+70°C
+85°C
Supply Voltage
X88064
X88064-60
Limits
5V ±10%
5V ±10%
7023 FRM T03
7023 FRM T04
D.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified.)
Symbol
Parameter
Min.
Limits
Max.
Units
Test Conditions
ICC
VCC Current (Active)
ISB1(CMOS) VCC Current (Standby)
ISB2(TTL)
ILI
ILO
VlL(3)
VIH(3)
VOL
VOH
VCC Current (Standby)
Input Leakage Current
Output Leakage Current
Input LOW Voltage
Input HIGH Voltage
Output LOW Voltage
Output HIGH Voltage
30
mA
CE = RD = VIL, All I/O’s = Open,
Other Inputs = VCC
150
µA
CE = VCC – 0.3V, All I/O’s = Open,
Other Inputs = VCC – 0.3V, ALE = VIL
2.5
mA
CE = VIH, All I/O’s = Open,
Other Inputs = VIH, ALE = VIL
10
µA VIN = VSS to VCC
10
µA VOUT = VSS to VCC, RD = VIH = PSEN
–1
0.8
V
2
VCC + 0.5
V
0.4
2.4
V IOL = 2.1 mA
V IOH = –400 µA
CAPACITANCE TA = +25°C, f = 1MHz, VCC = 5V
Symbol
Test
Max.
Units
7023 FRM T05
Conditions
CI/O(4)
CIN(4)
Input/Output Capacitance
Input Capacitance
10
pF
6
pF
VI/O = 0V
VIN = 0V
POWER-UP TIMING
7023 FRM T06
Symbol
Parameter
Max.
Units
tPUR(4)
tPUW(4)
Power-Up to Read
Power-Up to Write
1
ms
5
ms
7032 FRM T07
Notes: (3) VIL min. and VIH max. are for reference only and are not tested.
(4) This parameter is periodically sampled and not 100% tested.