English
Language : 

X24C01 Datasheet, PDF (9/14 Pages) Xicor Inc. – Serial E2PROM
X24C01
A.C. CHARACTERISTICS (Over recommended operating conditions, unless otherwise specified)
Read & Write Cycle Limits
Symbol
Parameter
Min.
Max.
Units
fSCL
SCL Clock Frequency
TI
Noise Suppression Time
Constant at SCL, SDA Inputs
0
100
KHz
100
ns
tAA
SCL Low to SDA Data Out Valid
0.3
3.5
µs
tBUF
Time the Bus Must Be Free Before a
4.7
µs
New Transmission Can Start
tHD:STA
tLOW
tHIGH
tSU:STA
tHD:DAT
tSU:DAT
tR
Start Condition Hold Time
Clock Low Period
Clock High Period
Start Condition Setup Time
Data In Hold Time
Data In Setup Time
SDA and SCL Rise Time
4.0
µs
4.7
µs
4.0
µs
4.7
µs
0
µs
250
ns
1
µs
tF
tSU:STO
tDH
SDA and SCL Fall Time
Stop Condition Setup Time
Data Out Hold Time
300
4.7
300
ns
µs
ns
3837 PGM T06
POWER-UP TIMING
Symbol
Parameter
Max.
Units
tPUR(4)
tPUW(4)
Bus Timing
Power-up to Read Operation
Power-up to Write Operation
1
ms
5
ms
3837 PGM T07
SCL
SDA IN
tSU:STA
SDA OUT
tF
tHIGH
tLOW
tHD:STA tHD:DAT
tSU:DAT
tAA
tDH
tR
tSU:STO
tBUF
3837 FHD F04
Note: (4) tPUR and tPUW are the delays required from the time VCC is stable until the specified operation can be initiated. These parameters
are periodically sampled and not 100% tested.