ABSOLUTE MAXIMUM RATINGS*
Temperature Under Bias .................. –65°C to +135°C
Storage Temperature ....................... –65°C to +150°C
Voltage on any Pin with
Respect to VSS ............................ –1.0V to +7.0V
D.C. Output Current ............................................ 5 mA
Lead Temperature
(Soldering, 10 Seconds) ............................. 300°C
RECOMMENDED OPERATING CONDITIONS
Temperature
Commercial
Industrial
Military
Min.
0°C
–40°C
–55°C
Max.
70°C
+85°C
+125°C
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation of
the device at these or any other conditions above those
indicated in the operational sections of this specification is
not implied. Exposure to absolute maximum rating condi-
tions for extended periods may affect device reliability.
Supply Voltage
X24C01
X24C01-3.5
X24C01-3
X24C01-2.7
Limits
4.5V to 5.5V
3.5V to 5.5V
3.0V to 5.5V
2.7V to 5.5V
D.C. OPERATING CHARACTERISTICS (Over recommended operating conditions, unless otherwise specified)
Limits
Symbol
Parameter
Min.
Max. Units
Test Conditions
ICC(1)
ICC(2)
ISB1(1)
VCC Supply Current (Read)
VCC Supply Current (Write)
VCC Standby Current
1
mA
2
100
µA
ISB2(1)
ILI
ILO
VlL(2)
VIH(2)
VOL
VCC Standby Current
Input Leakage Current
Output Leakage Current
Input Low Voltage
Input High Voltage
Output Low Voltage
50
µA
10
µA
10
µA
–1.0 VCC x 0.3 V
VCC x 0.7 VCC + 0.5 V
0.4
V
CAPACITANCE TA = 25°C, f = 1.0 MHz, VCC = 5V
SCL = VCC x 0.1/VCC x 0.9 Levels
@ 100 KHz, SDA = Open
SCL = SDA = VCC,
VCC = 5V ± 10%
SCL = SDA = VCC, VCC = 2.7V
VIN = GND to VCC
VOUT = GND to VCC
IOL = 2.1 mA
3837 PGM T03
Symbol
Parameter
Max. Units
Test Conditions
CI/O(3)
CIN(3)
Input/Output Capacitance (SDA)
Input Capacitance (SCL)
Notes: (1) Must perform a stop command prior to measurement.
(2) VIL min. and VIH max. are for reference only and are not tested.
(3) This parameter is periodically sampled and not 100% tested.
8
pF
6
pF
VI/O = 0V
VIN = 0V
3837 PGM T05
8