English
Language : 

X24022 Datasheet, PDF (9/14 Pages) Xicor Inc. – Serial E2PROM
X24022
ABSOLUTE MAXIMUM RATINGS*
Temperature Under Bias .................. –65°C to +135°C
Storage Temperature ....................... –65°C to +150°C
Voltage on any Pin with
Respect to VSS ............................... –1.0V to +7V
D.C. Output Current ............................................ 5 mA
Lead Temperature
(Soldering, 10 Seconds) ............................. 300°C
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation of
the device at these or any other conditions above those
indicated in the operational sections of this specification is
not implied. Exposure to absolute maximum rating condi-
tions for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
Temperature
Min.
Max.
Supply Voltage
Limits
Commercial
0°C
70°C
X24022
4.5V to 5.5V
Industrial
–40°C
+85°C
X24022-3
3V to 5.5V
Military
–55°C
+125°C
X24022-2.7
2.7V ± 5.5V
3848 PGM T02
3848 PGM T03
D.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified)
Symbol
Parameter
Limits
Min.
Max.
Units
Test Conditions
lCC1
lCC2
ISB(1)
ISB(2)
ILI
ILO
VlL(2)
VIH(2)
VOL
Power Supply Current (read)
1
mA
Power Supply Current (write)
Standby Current
2
50
µA
Standby Current
30
µA
Input Leakage Current
Output Leakage Current
Input Low Voltage
Input High Voltage
Output Low Voltage
10
µA
10
µA
–1.0 VCC x 0.3 V
VCC x 0.7 VCC + 0.5 V
0.4
V
SCL = VCC x 0.1/VCC x 0.9 Levels @
100 KHz, SDA = Open, All Other
Inputs = GND or VCC – 0.3V
SCL = SDA = VCC – 0.3V, All Other
Inputs = GND or VCC, VCC = 5.5V
SCL = SDA = VCC – 0.3V, All Other
Inputs = GND or VCC, VCC= 3V
VIN = GND to VCC
VOUT = GND to VCC
IOL = 3 mA
3848 PGM T04
CAPACITANCE TA = 25°C, f = 1.0 MHz, VCC = 5V
Symbol
Test
Max.
Units
Conditions
CI/O(3)
CIN(3)
Input/Output Capacitance (SDA)
Input Capacitance (A0, A1, A2, SCL)
8
pF
6
pF
Notes: (1) Must perform a stop command prior to measurement.
(2) VIL min. and VIH max. are for reference only and are not tested.
(3) This parameter is periodically sampled and not 100% tested.
VI/O = 0V
VIN = 0V
3848 PGM T06
9