English
Language : 

X24022 Datasheet, PDF (10/14 Pages) Xicor Inc. – Serial E2PROM
X24022
A.C. CONDITIONS OF TEST
Input Pulse Levels
Input Rise and
Fall Times
Input and Output
Timing Levels
VCC x 0.1 to VCC x 0.9
10 ns
VCC x 0.5
3848 PGM T02
EQUIVALENT A.C. LOAD CIRCUIT
5.0V
1533Ω
Output
100pF
3848 FHD F18
A.C. CHARACTERISTICS LIMITS (Over recommended operating conditions unless otherwise specified)
Read & Write Cycle Limits
Symbol
Parameter
Min.
Max. Units
fSCL
SCL Clock Frequency
0
TI
Noise Suppression Time Constant at SCL, SDA Inputs
tAA
SCL Low to SDA Data Out Valid
0.3
tBUF
Time the Bus Must Be Free Before a New Transmission Can Start 4.7
tHD:STA Start Condition Hold Time
4.0
tLOW
Clock Low Period
4.7
tHIGH
Clock High Period
4.0
tSU:STA Start Condition Setup Time
4.7
tHD:DAT Data In Hold Time
0
tSU:DAT Data In Setup Time
250
tR
SDA and SCL Rise Time
tF
SDA and SCL Fall Time
tSU:STO Stop Condition Setup Time
4.7
tDH
Data Out Hold Time
300
POWER-UP TIMING
100
KHz
100
ns
3.5
µs
µs
µs
µs
µs
µs
µs
ns
1
µs
300
ns
µs
ns
3848 PGM T08
Symbol
Parameter
Max.
Units
tPUR(4)
tPUW(4)
Bus Timing
Power-Up to Read Operation
Power-Up to Write Operation
1
ms
5
ms
3848 PGM T09
tF
tHIGH
tLOW
tR
SCL
tSU:STA
tHD:STA tHD:DAT
tSU:DAT
tSU:STO
SDA IN
tAA
tDH
tBUF
SDA OUT
3848 FHD F04
Notes: (4) tPUR and tPUW are the delays required from the time VCC is stable until the specified operation can be initiated. These parameters
are periodically sampled and not 100% tested.
10