ABSOLUTE MAXIMUM RATINGS*
*COMMENT
Temperature under Bias ........................–65°C to +135°C
Storage Temperature .............................–65°C to +150°C
Voltage on any Pin with Respect to VSS....... –1.0V to +7V
D.C. Output Current ....................................................5mA
Lead Temperature (Soldering, 10 seconds)............ 300°C
RECOMMENDED OPERATING CONDITIONS
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation of
the device at these or any other conditions above those
listed in the operational sections of this specification is not
implied. Exposure to absolute maximum rating conditions
for extended periods may affect device reliability.
Temp
Commercial
Industrial
Min.
0°C
–40°C
Max.
70°C
+85°C
Supply Voltage
X25xxx–1.8
X25xxx–2.7
Limits
1.8V-3.6V
2.7V to 5.5V
7036 FRM T07
X25xxx
4.5V-5.5V
7036 FRM T08
D.C. OPERATING CHARACTERISTICS (Over the recommended operating conditions unless otherwise specified.)
Symbol
Parameter
ICC1 VCC Write Current (Active)
Limits
Min. Typ. Max.
5
Units
Test Conditions
mA
SCK = VCC x 0.1/VCC x 0.9 @ 2MHz,
SO = Open
ICC2 VCC Read Current (Active)
0.4
mA
SCK = VCC x 0.1/VCC x 0.9 @ 2MHz,
SO = Open
ISB1 VCC Standby Current WDT=OFF
1
µA CS = VCC, VIN = VSS or VCC, VCC = 5.5V
ISB2 VCC Standby Current WDT=ON
50
µA CS = VCC, VIN = VSS or VCC, VCC = 5.5V
ISB3 VCC Standby Current WDT=ON
20
µA CS = VCC, VIN = VSS or VCC, VCC =3.6V
ILI
Input Leakage Current
0.1 10
µA VIN = VSS to VCC
ILO
Output Leakage Current
0.1 10
µA VOUT = VSS to VCC
VIL(1)
VIH(1)
VOL1
Input LOW Voltage
Input HIGH Voltage
Output LOW Voltage
–0.5
VCCx0.7
VCCx0.3 V
VCC+0.5 V
0.4
V VCC > 3.3V, IOL = 2.1mA
VOL2 Output LOW Voltage
0.4
V 2V < VCC ≤ 3.3V, IOL = 1mA
VOL3 Output LOW Voltage
0.4
V VCC ≤ 2V, IOL = 0.5mA
VOH1 Output HIGH Voltage
VCC–0.8
V VCC > 3.3V, IOH = –1.0mA
VOH2 Output HIGH Voltage
VCC–0.4
V 2V < VCC ≤ 3.3V, IOH = –0.4mA
VOH3 Output HIGH Voltage
VCC–0.2
V VCC ≤ 2V, IOH = –0.25mA
VOLRS Reset Output LOW Voltage
0.4
V IOL = 1mA
POWER-UP TIMING
7036 FRM T09
Symbol
tPUR(2)
tPUW(2)
Parameter
Power-up to Read Operation
Power-up to Write Operation
CAPACITANCE TA = +25°C, f = 1MHz, VCC = 5V.
Symbol
Test
COUT(2) Output Capacitance (SO, RESET, RESET)
CIN(2)
Input Capacitance (SCK, SI, CS, WP)
Notes: (1) VIL min. and VIH max. are for reference only and are not tested.
(2) This parameter is periodically sampled and not 100% tested.
Min.
Max.
8
6
Max.
1
5
Units
pF
pF
Units
ms
ms
7036 FRM T10
Conditions
VOUT = 0V
VIN = 0V
7036 FRM T11