ABSOLUTE MAXIMUM RATINGS*
Temperature under Bias .................. –65°C to +135°C
Storage Temperature ....................... –65°C to +150°C
Voltage on any Pin with Respect to VSS ......... –1V to +7V
D.C. Output Current ............................................. 5mA
Lead Temperature
(Soldering, 10 seconds) .............................. 300°C
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation of
the device at these or any other conditions above those
listed in the operational sections of this specification is not
implied. Exposure to absolute maximum rating condi-
tions for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
Temp
Commercial
Industrial
Military
Min.
0°C
–40°C
–55°C
Max.
+70°C
+85°C
+125°C
6556 PGM T05
Supply Voltage
X25041
X25041-3
X25041-2.7
Limits
5V ±10%
3V to 5.5V
2.7 to 5.5V
6556 PGM T06
D.C. OPERATING CHARACTERISTICS (Over the recommended operating conditions unless otherwise specified.)
Symbol Parameter
ICC VCC Supply Current (Active)
Limits
Min.
Max.
3
Units
mA
ISB
VCC Supply Current (Standby)
150
µA
ILI
Input Leakage Current
10
µA
ILO
VIL(1)
VIH(1)
Output Leakage Current
Input LOW Voltage
Input HIGH Voltage
10
µA
–1 VCC x 0.3 V
VCC x 0.7 VCC + 0.5 V
VOL Output LOW Voltage
0.4
V
VOH Output HIGH Voltage
VCC–0.8
V
Test Conditions
SCK = VCC x 0.1/VCC x 0.9 @ 1MHz,
SO = Open
CS = VCC, VIN = VSS or VCC – 0.3V
VIN = VSS to VCC
VOUT = VSS to VCC
IOL = 2mA
IOH = –1mA
6556 PGM T07.1
POWER-UP TIMING
Symbol
tPUR(2)
tPUW(2)
Parameter
Power-up to Read Operation
Power-up to Write Operation
Min.
CAPACITANCE TA = +25°C, f = 1MHz, VCC = 5V.
Symbol
COUT(2)
CIN(2)
Test
Output Capacitance (SO)
Input Capacitance (SCK, SI, CS, WP, HOLD)
Notes: (1) VIL min. and VIH max. are for reference only and are not tested.
(2) This parameter is periodically sampled and not 100% tested.
Max.
8
6
Max.
1
5
Units
ms
ms
6556 PGM T08
Units
pF
pF
Conditions
VOUT = 0V
VIN = 0V
6556 PGM T09