X9400
Figure 8. Increment/Decrement Timing Limits
SCK
SI
tWRID
VW/RW
Voltage Out
INC/DEC CMD Issued
Table 1. Instruction Set
Instruction Set
Instruction
I3 I2 I1 I0 R1 R0 P1 P0
Operation
Read Wiper Counter Register 1 0 0 1 0 0 P1 P0 Read the contents of the Wiper Counter Register
pointed to by P1-P0
Write Wiper Counter Register 1 0 1 0 0 0 P1 P0 Write new value to the Wiper Counter Register
pointed to by P1-P0
Read Data Register
1 0 1 1 R1 R0 P1 P0 Read the contents of the Data Register pointed
to by P1-P0 and R1–R0
Write Data Register
1 1 0 0 R1 R0 P1 P0 Write new value to the Data Register pointed to
by P1-P0 and R1–R0
XFR Data Register to Wiper
Counter Register
1 1 0 1 R1 R0 P1 P0 Transfer the contents of the Data Register pointed
to by R1–R0 to the Wiper Counter Register pointed
to by P1-P0
XFR Wiper Counter Register 1 1 1 0 R1 R0 P1 P0 Transfer the contents of the Wiper Counter
to Data Register
Register pointed to by P1-P0 to the Register
pointed to by R1–R0
Global XFR Data Register to
Wiper Counter Register
0 0 0 1 R1 R0 0
0 Transfer the contents of the Data Registers
pointed to by R1–R0 of all four pots to their
respective Wiper Counter Register
Global XFR Wiper Counter
Register to Data Register
Increment/Decrement Wiper
Counter Register
Read Status (WIP bit)
1 0 0 0 R1 R0 0 0 Transfer the contents of all Wiper Counter
Registers to their respective data Registers
pointed to by R1–R0 of all four pots
0 0 1 0 0 0 P1 P0 Enable Increment/decrement of the Wiper
Counter Register pointed to by P1-P0
0 1 0 1 0 0 0 1 Read the status of the internal write cycle, by
checking the WIP bit.
REV 1.1.4 10/11/02
www.xicor.com
Characteristics subject to change without notice. 7 of 22