X9400 Datasheet, PDF (10/22 Pages) Xicor Inc. – Quad Digitally Controlled Potentiometers (XDCP) | |||
|
◁ |
X9400
ABSOLUTE MAXIMUM RATINGS
Temperature under bias.................... â65°C to +135°C
Storage temperature......................... â65°C to +150°C
Voltage on SCK, SCL or any address
input with respect to VSS ........................ â1V to +7V
Voltage on V+ (referenced to VSS) .........................10V
Voltage on V- (referenced to VSS) ........................ -10V
(V+) â (V-) ..............................................................12V
Any VH .....................................................................V+
Any VL ......................................................................V-
Lead temperature (soldering, 10 seconds) ........ 300°C
IW (10 seconds) ................................................±12mA
RECOMMENDED OPERATING CONDITIONS
Temperature
Commercial
Industrial
Min.
0°C
â40°C
Max.
+70°C
+85°C
COMMENT
Stresses above those listed under âAbsolute Maximum
Ratingsâ may cause permanent damage to the device.
This is a stress rating only; functional operation of the
device (at these or any other conditions above those
listed in the operational sections of this speciï¬cation) is
not implied. Exposure to absolute maximum rating
conditions for extended periods may affect device
reliability.
Device
X9400
X9400-2.7
Supply Voltage (VCC) Limits
5V ±10%
2.7V to 5.5V
ANALOG CHARACTERISTICS (Over recommended operating conditions unless otherwise stated.)
Symbol
RTOTAL
IW
RW
Vv+
Vv-
VTERM
CH/CL/CW
IAL
Parameter
End to end resistance
Power rating
Wiper current
Wiper resistance
Voltage on V+ Pin X9400
X9400-2.7
Voltage on V- Pin X9400
X9400-2.7
Voltage on any VH/RH or VL/RL Pin
Noise
Resolution
Absolute linearity (1)
Relative linearity (2)
Temperature coefficient of RTOTAL
Ratiometric temp. coefficient
Potentiometer capacitances
RH, RL, RW leakage current
Min.
+4.5
+2.7
-5.5
-5.5
V-
-1
-0.2
Limits
Typ. Max.
±20
50
±6
150
250
40
100
-120
1.6
±300
10/10/25
0.1
+5.5
+5.5
-4.5
-2.7
V+
+1
+0.2
±20
10
Unit
%
mW
mA
â¦
â¦
V
Test Conditions
25°C, each pot
Wiper Current = ± 1mA,
VCC = 3V
Wiper Current = ± 1mA,
VCC = 5V
V
V
dBV
%
MI(3)
MI(3)
ppm/°C
ppm/°C
pF
µA
Ref: 1kHz
Rw(n)(actual)âRw(n)(expected)
Rw(n + 1)â[Rw(n) + MI]
See Spice Macromodel
VIN = VSS to VCC. Device is in
stand-by mode.
Notes: (1) Absolute linearity is utilized to determine actual wiper voltage versus expected voltage as determined by wiper position when
used as a potentiometer.
(2) Relative linearity is utilized to determine the actual change in voltage between two successive tap positions when used as a
potentiometer. It is a measure of the error in step size.
(3) MI = RTOT/63 or (RHâRL)/63, single pot
REV 1.1.4 10/11/02
www.xicor.com
Characteristics subject to change without notice. 10 of 22
|
▷ |