English
Language : 

X9514 Datasheet, PDF (6/11 Pages) Xicor Inc. – PushPot™ Potentiometer (Push Button Controlled)
X9514
A.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified)
Limits
Symbol
Parameter
Min. Typ.(6) Max. Units
tGAP
tDB
tS SLOW
tS FAST(7)
tPU(7)
tR Vcc(7)
tASTO(7)
VASTH(7)
VASEND(7)
Time Between Two Separate Push Button Events
Debounce Time
After Debounce to Wiper Change on a Slow Mode
Wiper Change on a Scan Mode
Power Up to Wiper Stable
VCC Power-up Rate
AUTOSTORE Cycle Time
AUTOSTORE Threshold Voltage
AUTOSTORE Cycle End Voltage
0
µs
60
ms
100
250
375 ms
25
50
75
ms
500
µs
0.2
50 mV/µs
2
ms
4
V
3.5
V
6487 PGM T07.3
AUTOSTORE Cycle Timing Diagram
5
VCC
VASTH
AUTOSTORE CYCLE IN PROGRESS
VASEND
tASTO
STORE TIME
TIME (ms)
6487 ILL F03.2
Notes: VASTH – AUTOSTORE threshold voltage
VASEND – AUTOSTORE cycle end voltage
tASTO – AUTOSTORE cycle time
(6) Typical values are for TA = 25°C and nominal supply voltage.
(7) This parameter is periodically sampled and not 100% tested.
6