English
Language : 

X9514 Datasheet, PDF (5/11 Pages) Xicor Inc. – PushPot™ Potentiometer (Push Button Controlled)
X9514
RECOMMENDED OPERATING CONDITIONS
Temperature
Min.
Max.
Commercial
Industrial
Military
0°C
–40°C
–55°C
+70°C
+85°C
+125°C
6487 PGM T03.1
Supply Voltage
X9514
Limits
5V ±10%
6487 PGM T04.1
D.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified.)
Symbol
ICC
ISB
ILI
VIH
VIL
RW
VVH
VVL
CIN(5)
Parameter
VCC Active Current
Standby Supply Current
ASE, PU, PD Input
Leakage Current
ASE, PU, PD Input
HIGH Voltage
ASE, PU, PD Input
LOW Voltage
Wiper Resistance
VH Terminal Voltage
VL Terminal Voltage
ASE, PU, PD Input
Capacitance
Min.
2
–1
–5
–5
Limits
Typ.(4)
1
Max.
3
200
10
Units
mA
µA
µA
Test Conditions
PU or PD held at VIL the others at VIH
PU = PD = VH
VIN = VSS to VCC
VCC + 1 V
0.8
V
40
100
Ω Max. Wiper Current ±1mA
+5
V
+5
V
10
pF VCC = 5V, VIN = 0V,
TA = 25°C, f = 1MHz
6487 PGM T05.4
STANDARD PARTS
Part Number
Maximum Resistance
Wiper Increments
X9514W
10KΩ
Notes: (4) Typical values are for TA = 25°C and nominal supply voltage.
(5) This parameter is periodically sampled and not 100% tested.
Log Taper
SYMBOL TABLE
Minimum Resistance
40Ω
6487 PGM T08.1
WAVEFORM INPUTS
OUTPUTS
Must be
steady
May change
from LOW
to HIGH
May change
from HIGH
to LOW
Don’t Care:
Changes
Allowed
N/A
Will be
steady
Will change
from LOW
to HIGH
Will change
from HIGH
to LOW
Changing:
State Not
Known
Center Line
is High
Impedance
5