X9116
A.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified)
Symbol
tCl
tlD
tDI
tlL
tlH
tlC
tCPH
tIW
tCYC
tR, tF(7)
tPU(7)
tR VCC(7)
tWR
Parameter
CS to INC setup
INC HIGH to U/D change
U/D to INC setup
INC LOW period
INC HIGH period
INC inactive to CS inactive
CS deselect time (STORE)
INC to Vw change
INC cycle time
INC input rise and fall time
Power up to wiper stable
VCC Power-up rate
Store cycle
Min.
100
100
2.9
1
1
1
10
4
15
Limits
Typ.(6)
1
5
Max.
5
500
5
50
10
Unit
ns
ns
µs
µs
µs
µs
ms
µs
µs
µs
µs
mV/µs
ms
POWER UP AND DOWN REQUIREMENTS
There are no restrictions on the power-up or power-down conditions of VCC and the voltages applied to the potenti-
ometer pins provided that VCC is always more positive than or equal to VH, VL, and VW, i.e., VCC ≥ VH, VL, VW. The
VCC ramp rate spec is always in effect.
A.C. TIMING
CS
tCI
INC
U/D
tIW
VW
tCYC
tIL
tIH
tID
(store)
tIC
tCPH
tDI
MI (8)
90% 90%
10%
tF
tR
Notes: (6) Typical values are for TA = 25°C and nominal supply voltage.
(7) This parameter is not 100% tested.
(8) MI in the A.C. timing diagram refers to the minimum incremental change in the VW output due to a change in the wiper position.
REV 1.2 2/5/03
www.xicor.com
Characteristics subject to change without notice. 6 of 11