English
Language : 

X9116 Datasheet, PDF (4/11 Pages) Xicor Inc. – Digitally Controlled Potentiometer (XDCP)
X9116
ABSOLUTE MAXIMUM RATINGS
Temperature under bias ....................–65°C to +135°C
Storage temperature .........................–65°C to +150°C
Voltage on CS, INC, U/D, VH/RH, VL/RL
and VCC with respect to VSS................... –1V to +7V
∆V = |VH/RH–VL/RL| ............................................ 5.5V
Lead temperature (soldering 10 seconds)..........300°C
IW (10 seconds) ............................................ ±10.0mA
RECOMMENDED OPERATING CONDITIONS
Temperature
Commercial
Industrial
Min.
0°C
–40°C
Max.
+70°C
+85°C
COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only; the functional operation of
the device (at these or any other conditions above
those listed in the operational sections of this specifi-
cation) is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect
device reliability.
Supply Voltage (VCC)
X9116
X9116-2.7
Limits
5V ±10%
2.7V to 5.5V
POTENTIOMETER CHARACTERISTICS (Over recommended operating conditions unless otherwise stated)
Symbol
Parameter
RTOTAL
VVH
VVL
End to end resistance variation
VH/RH terminal voltage
VL/RL terminal voltage
Power rating
RW
Wiper resistance
RW
Wiper resistance
IW
Wiper current
Noise
Resolution
Absolute linearity(1)
Relative linearity(2)
RTOTAL temperature coefficient
Ratiometric temperature coefficient
CH/CL/CW Potentiometer capacitances
Min.
–20
VSS
VSS
-5.0
-1
-0.2
Limits
Typ. Max.
+20
VCC
VCC
10
200
400
400
1000
+5.0
-120
6
+1
+0.2
±300
±20
10/10/25
Unit Test Conditions/Notes
%
V
VSS = 0V
V
VSS = 0V
mW RTOTAL = 10 KΩ
Ω
IW = 1mA, VCC = 5V
Ω
IW = 1mA, VCC = 2.7V
mA
dBV√Hz Ref: 1kHz
%
MI(3)
MI(3)
ppm/°C
Vw(n)(actual)–Vw(n)(expected)
Vw(n+1)–[Vw(n)+MI]
ppm/°C
pF See Circuit #3
Notes: (1) Absolute linearity is utilized to determine actual wiper voltage versus expected voltage = (Vw(n)(actual)–Vw(n)(expected)) = ±1
Ml Maximum.
(2) Relative linearity is a measure of the error in step size between taps = VW(n+1)–[Vw(n) + Ml] = ±0.2 Ml.
(3) 1 Ml = Minimum Increment = RTOT/15.
REV 1.2 2/5/03
www.xicor.com
Characteristics subject to change without notice. 4 of 11