POWER UP TIMING (DIGITAL INPUTS FLOATING, INTERNAL PULLUP ACTION SHOWN)
VCC = 3.3 or 5.0V
VCC
tRVCC
CS
INC
U/D
POWER UP AND DOWN REQUIREMENTS
There are no restrictions on the power-up or power-down conditions of VCC and the voltages applied to the Cp, Cm
pins provided that VCC is always more positive than or equal to VCp, VCm, i.e., VCC ≥ VCp, VCm. The VCC ramp rate
spec is always in effect.
Powerup Requirements
In order to prevent unwanted tap position changes or an inadvertant store, bring the CS and INC high before or
concurrently with the VCC pin. The logic inputs have internal active pullups to provide reliable powerup operation.
See powerup timing diagram.