English
Language : 

X90100 Datasheet, PDF (4/10 Pages) Xicor Inc. – NV Electronically Programmable Capacitor
X90100
D.C. OPERATING CHARACTERISTICS (VCC = 5V, TA = 25°C unless otherwise specified)
Limits
Symbol
Parameter
Min. Typ.(4) Max. Unit
Test Conditions
I CC1
I CC2
I SB
I LI
VCC active current (Increment)
VCC active current (Store) (EE-
PROM Store)
Standby supply current
CS, INC, U/D input leakage
current
50
100
µA CS = VIL, U/D = VIL or VIH and
INC = 0.4V @ max. tCYC
250
500
µA CS = VIH, U/D = VIL or VIH and
INC = VIH @ max. tWR
0.5
2
µA CS = VCC – 0.3V, U/D and
INC = VSS or VCC – 0.3V
-15
µA VIN = VSS
V IH
VIL
CIN(5)
CS, INC, U/D input HIGH voltage
CS, INC, U/D input LOW voltage
CS, INC, U/D input capacitance
VCC x 0.7
–0.5
VCC + 0.5 V
VCC x 0.1 V
10
pF VCC = 5V, VIN = VSS,
TA = 25°C, f = 1MHz
ENDURANCE AND DATA RETENTION (VCC = 5V, TA = 25°C unless otherwise specified)
Parameter
Min.
Unit
Minimum endurance
100,000
Data changes per bit
Data retention
100
Years
A.C. CONDITIONS OF TEST
Input pulse levels
Input rise and fall times
Input reference levels
0V to 3V
10ns
1.5V
REV 1.4.7 9/8/03
www.xicor.com
4 of 10