English
Language : 

X24C00 Datasheet, PDF (6/11 Pages) Xicor Inc. – Serial E2PROM
X24C00
POWER-UP TIMING
Symbol
tPUR(3)
tPUW(3)
Parameter
Power-up to Read Operation
Power-up to Write Operation
Max.
2
5
Units
ms
ms
3836 PGM T08
EQUIVALENT A.C. LOAD CIRCUIT
5V
2.16KΩ
OUTPUT
3.07KΩ
100pF
A.C. CONDITIONS OF TEST
Input Pulse Levels
Input Rise and
Fall Times
Input and Output
Timing Levels
VCC x 0.1 to VCC x 0.9
10ns
VCC x 0.5
3836 PGM T06.1
3836 FHD F09.2
A.C. CHARACTERISTICS (Over the recommended operating conditions unless otherwise specified.)
Read & Write Cycle Limits
Symbol
Parameter
Min.
Max.
Units
fSCL
SCL Clock Frequency
0
1
MHz
tAA
SCL LOW to SDA Data Out Valid
350
ns
tBUF
Time the Bus Must Be Free Before a
500
ns
New Transmission Can Start
tHD:STA
tLOW
tHIGH
tSU:STA
tHD:DAT
tSU:DAT
tR
tF
tSU:STO
tDH
Start Condition Hold Time
Clock LOW Period
Clock HIGH Period
Start Condition Setup Time
Data In Hold Time
Data in Setup Time
SDA and SCL Rise Time
SDA and SCL Fall Time
Stop Condition Setup Time
Data Out Hold Time
250
ns
500
ns
500
ns
250
ns
0
µs
250
ns
1
µs
300
ns
250
ns
50
ns
3836 PGM T07.1
Note: (3) tPUR and tPUW are the delays required from the time VCC is stable until the specified operation can be initiated. These parameters
are periodically sampled and not 100% tested.
6