English
Language : 

X24C00 Datasheet, PDF (5/11 Pages) Xicor Inc. – Serial E2PROM
X24C00
ABSOLUTE MAXIMUM RATINGS*
Temperature under Bias
X24C00 ...................................... –65°C to +135°C
Storage Temperature ....................... –65°C to +150°C
Voltage on any Pin with
Respect to VSS ............................................ –1V to +7V
D.C. Output Current ............................................. 5mA
Lead Temperature
(Soldering, 10 seconds) .............................. 300°C
RECOMMENDED OPERATING CONDITIONS
Temperature
Min.
Max.
Commercial
Industrial
Military
0°C
–40°C
–55°C
+70°C
+85°C
+125°C
3836 PGM T02.1
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation of
the device at these or any other conditions above those
indicated in the operational sections of this specification is
not implied. Exposure to absolute maximum rating condi-
tions for extended periods may affect device reliability.
Supply Voltage
X24C00
X24C00-3
X24C00-2.7
Limits
5V ±10%
3V to 5.5V
2.7V to 5.5V
3836 PGM T03.1
D.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified.)
Symbol
Parameter
Limits
Min.
Max.
Units
Test Conditions
lCC1
ICC2
ISB1
ISB2
ILI
ILO
VlL(1)
VIH(1)
VOL
VOH
VCC Supply Current Read
VCC Supply Current Write
VCC Standby Current
1
mA
3
100
µA
VCC Standby Current
50
µA
Input Leakage Current
10
µA
Output Leakage Current
10
µA
Input LOW Voltage
Input HIGH Voltage
Output LOW Voltage
–1
VCC x 0.3 V
VCC x 0.7 VCC + 0.5 V
0.4
V
Output HIGH Voltage
VCC – 0.8
V
SCL = VCC x 0.1/VCC x 0.9
Levels @ 1MHz, SDA = Open
SCL = SDA = VCC
VCC = 5V ±10%
SCL = SDA = VCC
VCC = 2.7V
VIN = VSS to VCC
VOUT = VSS to VCC
IOL = 2.1mA
IOH = 1mA
3841 PGM T04.3
CAPACITANCE TA = +25°C, f = 1MHz, VCC = 5V
Symbol
Parameter
CI/O(2)
CIN(2)
Input/Output Capacitance (SDA)
Input Capacitance (SCL)
Notes: (1) VIL min. and VIH max. are for reference only and are not tested.
(2) This parameter is periodically sampled and not 100% tested.
Max.
8
6
Units
pF
pF
Test Conditions
VI/O = 0V
VIN = 0V
3836 PGM T05.1
5