ABSOLUTE MAXIMUM RATINGS*
Temperature under Bias
X2816C ....................................... –10°C to +85°C
X2816CI ..................................... –65°C to +135°C
Storage Temperature ....................... –65°C to +150°C
Voltage on any Pin with
Respect to VSS .................................. –1V to +7V
D.C. Output Current ............................................. 5mA
Lead Temperature (Soldering, 10 seconds)...... 300°C
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation of
the device at these or any other conditions above those
indicated in the operational sections of this specification is
not implied. Exposure to absolute maximum rating condi-
tions for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
Temperature
Min.
Max.
Commercial
Industrial
0°C
–40°C
+70°C
+85°C
3852 PGM T02.2
Supply Voltage
X2816C
Limits
5V ±10%
3852 PGM T03.1
D.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified.)
Symbol
ICC
ISB1
ILI
ILO
VlL(2)
VIH(2)
VOL
VOH
Parameter
VCC Current (Active)
Min.
Limits
Typ.(1) Max.
70
110
Units
mA
VCC Current (Standby)
35
50
mA
Input Leakage Current
Output Leakage Current
Input LOW Voltage
–1
Input HIGH Voltage
2
Output LOW Voltage
Output HIGH Voltage
2.4
10
µA
10
µA
0.8
V
VCC +1
V
0.4
V
V
Test Conditions
CE = OE = VIL
All I/O’s = Open
Other Inputs = VCC
CE = VIH, OE = VIL
All I/O’s = Open
Other Inputs = VCC
VIN = VSS to VCC
VOUT = VSS to VCC, CE = VIH
IOL = 2.1mA
IOH = –400µA
3852 PGM T02.2
Notes: (1) Typical values are for TA = 25°C and nominal supply voltage and are not tested.
(2) VIL min. and VIH max. are for reference only and are not tested.