X28HT512
ABSOLUTE MAXIMUM RATINGS*
Temperature under Bias
X28HT512 ................................. –40°C to +175°C
Voltage on any Pin with
Respect to VSS ....................................... –1V to +7V
D.C. Output Current ............................................. 5mA
Lead Temperature
(Soldering, 10 seconds) .............................. 300°C
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation of
the device at these or any other conditions above those
indicated in the operational sections of this specification is
not implied. Exposure to absolute maximum rating condi-
tions for extended periods may affect device reliability.
RECOMMEND OPERATING CONDITIONS
Temperature
Min.
Max.
High Temp
–40°C
+175°C
6614 PGM T02.1
Supply Voltage
X28HT512
Back Bias Voltage (VBB)
Limits
5V ±5%
–3V ±10%
6614 PGM T03.1
D.C. OPERATING CHARACTERISTICS (Over recommended operating conditions, unless otherwise specified.)
Limits
Symbol
ICC
Parameter
VCC Current (Active)
(TTL Inputs)
Min.
Max.
50
ISB1
ILI
ILO
VlL(1)
VIH(1)
VOL
VOH
VBB
VCC Current (Standby)
(TTL Inputs)
Input Leakage Current
Output Leakage Current
Input LOW Voltage
Input HIGH Voltage
Output LOW Voltage
Output HIGH Voltage
Back Bias Voltage
3
20
20
–1
0.6
2.2
VCC + 1
0.5
2.6
200
Notes: (1) VIL min. and VIH max. are for reference only and are not tested.
Units
mA
mA
µA
µA
V
V
V
V
µA
Test Conditions
CE = OE = VIL, WE = VIH,
All I/O’s = Open, Address Inputs =
.4V/2.4V Levels @ f = 5MHz
CE = VIH, OE = VIL
All I/O’s = Open, Other Inputs = VCC
VIN = VSS to VCC
VOUT = VSS to VCC, CE = VIH
IOL = 1mA
IOH = –400µA
VBB = –3V±10%