English
Language : 

X28LC512 Datasheet, PDF (11/19 Pages) Xicor Inc. – 3.3 Volt, Byte Alterable E2PROM
X28LC512/X28LC513
POWER-UP TIMING
Symbol
tPUR(2)
tPUW(2)
Parameter
Power-up to Read Operation
Power-up to Write Operation
CAPACITANCE TA = +25°C, f = 1MHz, VCC = 3.3V
Symbol
Parameter
CI/O(2)
CIN(2)
Input/Output Capacitance
Input Capacitance
ENDURANCE AND DATA RETENTION
Parameter
Min.
Endurance
Data Retention
10,000
100
Max.
100
5
Max.
10
10
Units
pF
pF
Max.
A.C. CONDITIONS OF TEST
Input Pulse Levels
0V to 3V
Input Rise and
Fall Times
Input and Output
Timing Levels
10ns
1.5V
3856 PGM T07.1
MODE SELECTION
CE
OE WE
L
L
H
L
H
L
H
X
X
X
L
X
X
X
H
Mode
Read
Write
Standby and
Write Inhibit
Write Inhibit
Write Inhibit
EQUIVALENT A.C. LOAD CIRCUIT
SYMBOL TABLE
Units
µs
ms
3005 PGM T05
Test Conditions
VI/O = 0V
VIN = 0V
3005 PGM T06.1
Units
Cycles per Byte
Years
3005 PGM T11
I/O
DOUT
DIN
High Z
Power
Active
Active
Standby
—
—
—
—
3005 PGM T08
5V
2.66KΩ
OUTPUT
4.46KΩ
30pF
3005 ILL F21.3
Note: (2) This parameter is periodically sampled and not 100%
tested.
WAVEFORM INPUTS
OUTPUTS
Must be
steady
May change
from LOW
to HIGH
May change
from HIGH
to LOW
Don’t Care:
Changes
Allowed
N/A
Will be
steady
Will change
from LOW
to HIGH
Will change
from HIGH
to LOW
Changing:
State Not
Known
Center Line
is High
Impedance
11