English
Language : 

X28LC512 Datasheet, PDF (10/19 Pages) Xicor Inc. – 3.3 Volt, Byte Alterable E2PROM
X28LC512/X28LC513
ABSOLUTE MAXIMUM RATINGS*
Temperature under Bias
X28LC512/513 ............................. –10°C to +85°C
X28LC512I/X28LC513I .............. –65°C to +135°C
Storage Temperature ....................... –65°C to +150°C
Voltage on any Pin with
Respect to VSS ....................................... –1V to +7V
D.C. Output Current ............................................. 5mA
Lead Temperature
(Soldering, 10 seconds) .............................. 300°C
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation of
the device at these or any other conditions above those
indicated in the operational sections of this specification is
not implied. Exposure to absolute maximum rating condi-
tions for extended periods may affect device reliability.
RECOMMEND OPERATING CONDITIONS
Temperature
Min.
Max.
Commercial
Industrial
0°C
–40°C
+70°C
+85°C
3005 PGM T02
Supply Voltage
X28LC512/513
Limits
3.3V ±10%
3005 PGM T03.1
D.C. OPERATING CHARACTERISTICS (Over recommended operating conditions, unless otherwise specified.)
Limits
Symbol
Parameter
Min.
Max. Units
Test Conditions
ICC
VCC Current (Active)
(CMOS Inputs)
25
mA CE = OE = VIL, WE = VIH,
All I/O’s = Open, Address Inputs =
0.1xVCC/0.9xVCC Levels
@ f = 5MHz
ISB
VCC Current (Standby)
(CMOS Inputs)
150
µA OE = VIL, CE = VCC – 0.3V
All I/O’s = Open, Other Inputs = VIH
ILI
Input Leakage Current
ILO
Output Leakage Current
10
µA VIN = VSS to VCC
10
µA VOUT = VSS to VCC, CE = VCC
VlL(1)
Input LOW Voltage
–1
0.6
V
VIH(1)
Input HIGH Voltage
2
VCC + 0.5 V
VOL
Output LOW Voltage
0.4
V IOL = 1mA
VOH
Output HIGH Voltage
2.4
V IOH = –200µA
Notes: (1) VIL min. and VIH max. are for reference only and are not tested.
3005 PGM T04.2
10