English
Language : 

X76F101 Datasheet, PDF (10/17 Pages) Xicor Inc. – Secure SerialFlash
X76F101
Nonvolatile Write Cycle Timing
Symbol
Parameter
Min.
Typ.(1)
Max.
Units
tWC(1)
Write Cycle Time
5
10
mS
Notes: 1. tWC is the time from a valid stop condition at the end of a write sequence to the end of the self-timed internal nonvolatile write cycle.
It is the minimum cycle time to be allowed for any nonvolatile write by the user, unless Acknowledge Polling is used.
BUS TIMING
SCL
SDA IN
tSU:STA
SDA OUT
tF
tHIGH
tLOW
tHD:STA tHD:DAT
t SU:DAT
tAA
t DH
tR
t SU:STO
t BUF
Write Cycle Timing
SCL
SDA
8th bit of last byte
ACK
tWC
Stop
Condition
Start
Condition
CS Timing Diagram (Selecting/Deselecting the Part)
SCL
CS
from
master
tSU:CS
tHD:CS
10