English
Language : 

I5216 Datasheet, PDF (60/83 Pages) Winbond – 8 TO 16 MINUTE VOICE RECORD/PLAYBACK SYSTEM WITH INTEGRATED CODEC
I5216 SERIES
Advanced Information
PRELIMINARY
I2C INTERFACE TIMING
PARAMETER
SYMBOL
SCL clock frequency
Hold time (repeated) START condition.
After this period, the first clock pulse is
generated
LOW period of the SCL clock
HIGH period of the SCL clock
Set-up time for a repeated START
condition
Data set-up time
Rise time of both SDA and SCL signals
Fall time of both SDA and SCL signals
Set-up time for STOP condition
Bus-free time between a STOP and
START condition
Capacitive load for each bus line
Noise margin at the LOW level for each
connected device (including hysteresis)
Noise margin at the HIGH level for each
connected device (including hysteresis)
fSCL
tHD; STA
tLOW
tHIGH
tSU; STA
tSU; DAT
tr
tf
tSU; STO
tBUF
Cb
VnL
VnH
STANDARD-MODE
MIN.
0
4.0
MAX.
100
-
4.7
4.0
4.7
250
-
-
4.0
4.7
-
0.1 VDD
0.2 VDD
-
-
-
-
1000
300
-
-
400
-
-
FAST-MODE
MIN.
0
0.6
MAX.
400
-
1.3
-
0.6
-
0.6
-
100(1)
-
20 + 0.1Cb(2)
300
20 + 0.1Cb(2)
300
0.6
-
1.3
-
-
400
0.1 VDD
-
0.2 VDD
-
UNIT
kHz
ns
ns
ns
ns
ns
ns
ns
ns
ns
pF
V
V
1. A Fast-mode I2C-interface device can be used in a Standard-mode I2C-interface system, but the
requirement tSU;DAT > 250 ns must then be met. This will automatically be the case if the device does
not stretch the LOW period of the SCL signal.
If such a device does stretch the LOW period of the SCL signal, it must output the next data
bit to the SDA line; tr max + tSU;DAT = 1000 + 250 = 1250 ns (according to the Standard-mode
I2C -interface specification) before the SCL line is released.
2. Cb = total capacitance of one bus line in pF. If mixed with HS mode devices, faster fall-times
are allowed.
Publication Release Date: November 30, 2001
- 60