7.23 PWMOUT2 Control Register -- Index 5Bh (Bank 0)
Register Location:
5Bh
Power on default value: <7:0> 1111-1111. Reset by MR.
Attribute:
Read/Write
Size:
8 bits
7 6 5 4 32 1 0
PWM2_DUTY
Bit 7: PWMOUT2 duty cycle control
Write FF, Duty cycle is 100%,
Write 00, Duty cycle is 0%.
7.24 PWMOUT1/2 Clock Select Register -- Index 5Ch (Bank 0)
Register Location:
Power on Default Value
Attribute:
Size:
5Ch
<7:0> 0001-0001. Reset by MR.
Read/Write
8 bits
7 6 5432 1 0
PWM2CLKSEL
PWM2CLKSEL
PWM2CLKSEL
EN_FANPWM1
PWM1CLKSEL
PWM1CLKSEL
PWM1CLKSEL
Reserved
Bit 7: Reserved
Bit 6-4: PWMOUT1 clock selection.
The clock defined frequency is same as PWMOUT2 clock selection.
- 40 -
Publication Release Date: Oct. 2004
Revision 1.1