9.2.11 Continuous Read Mode Bits (M7-0)
The “Continuous Read Mode” bits are used in conjunction with the “Fast Read Dual I/O” instruction to
provide the highest random Flash memory access rate with minimum SPI instruction overhead, thus
allow true XIP (execute in place) to be performed on serial flash devices.
M7-0 need to be set by the Dual I/O Read instruction. M5-4 are used to control whether the 8-bit SPI
instruction code BBh is needed or not for the next command. When M5-4 = (1,0), the next command
will be treated same as the current Dual I/O Read command without needing the 8-bit instruction
code; when M5-4 do not equal to (1,0), the device returns to normal SPI mode, all commands can be
accepted. M7-6 and M3-0 are reserved bits for future use, either 0 or 1 values can be used.
9.2.12 Continuous Read Mode Reset (FFFFh)
Continuous Read Mode Reset instruction can be used to set M4 = 1, thus the device will release the
Continuous Read Mode and return to normal SPI operation, as shown in figure 12.
/CS
CLK
Mode 3
Mode 0
Mode Bit Reset
for Dual I/O
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Mode 3
Mode 0
IO0
FFFFh
IO1
Don’t Care
Figure 12. Continuous Read Mode Reset for Fast Read Dual I/O
Since W25X10BV/20BV/40BV does not have a hardware Reset pin, so if the controller resets while
W25X10BV/20BV/40BV are set to Continuous Mode Read, the W25X10BV/20BV/40BV will
not recognize any initial standard SPI instructions from the controller. To address this possibility, it is
recommended to issue a Continuous Read Mode Reset instruction as the first instruction after a
system Reset. Doing so will release the device from the Continuous Read Mode and allow Standard
SPI instructions to be recognized.
To reset “Continuous Read Mode” during Dual I/O operation, sixteen clocks are needed to shift in
instruction “FFFFh”.