W39L512 Datasheet, PDF (18/25 Pages) Winbond – 64K 8 COMS FLASH MEMORY
W39L512
AC Characteristics, continued
Power-up Timing
PARAMETER
Power-up to Read Operation
Power-up to Write Operation
SYMBOL
TPU. READ
TPU. WRITE
TYPICAL
100
5
UNIT
µS
mS
Data Polling and Toggle Bit Timing Parameters
PARAMETER
#OE to Data Polling Output Delay
#CE to Data Polling Output Delay
#OE to Toggle Bit Output Delay
#CE to Toggle Bit Output Delay
SYM.
TOEP
TCEP
TOET
TCET
W39L512-70
MIN. MAX.
-
35
-
70
-
35
-
70
W39L512-90
MIN. MAX.
-
45
-
90
-
45
-
90
UNIT
nS
nS
nS
nS
- 18 -