English
Language : 

JFCW10 Datasheet, PDF (3/5 Pages) Wall Industries,Inc. – 10 Watt DC/DC Power Converters
Wall Industries, Inc.
Rev B
JFCW10 SERIES
10 Watt DC/DC Power Converters
TECHNICAL SPECIFICATIONS: JFCW10 SERIES
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
TEST CONDITIONS
Min Typ Max Unit
REMOTE ON/OFF (See Note 4)
Positive Logic (standard)
Negative Logic (optional)
Input Current of Remote Control Pin
Remote OFF State Input Current
ENVIRONMENTAL SPECIFICATIONS
Operating Ambient Temperature
Maximum Case Temperature
Storage Temperature
Thermal Impedance (See Note 6)
Relative Humidity
Thermal Shock
Vibration
MTBF
PHYSICAL SPECIFICATIONS
Weight
Dimensions (L x W x H)
Case Material
Base Material
Potting Material
Shielding
SAFETY & EMC CHARACTERISTICS
Safety Approvals
EMI (See Note 3)
ESD
Radiated Immunity
Fast Transient (See Note 2)
Surge (See Note 2)
Conducted Immunity
The CTRL pin is referenced to –Input pin
The CTRL pin is referenced to –Input pin
Nominal Vin
Nominal Vin
With derating
Natural Convection
MIL‐HDBK‐217F Ta=25°C, full load
EN55022
EN61000‐4‐2
EN61000‐4‐3
EN61000‐4‐4
EN61000‐4‐5
EN61000‐4‐6
DC/DC ON
DC/DC OFF
DC/DC ON
DC/DC OFF
Without Heatsink
With Heatsink
Air ±8kV
Contact ±6kV
10 V/m
±2kV
±1kV
3 Vrms
Open or 3V < Vr < 15 VDC
Short or 0V < Vr < 1.2 VDC
Short or 0V <Vr < 1.2 VDC
Open or 3V < Vr < 15 VDC
‐0.5
1.0
mA
2.5
mA
‐40
+85
°C
+105
°C
‐55
+125
°C
16.18
15.13
°C/W
5
95
% RH
MIL‐STD‐810F
MIL‐STD‐810F
3,376,000 hours
0.58oz (16.5g)
1.00x1.00x0.39 inch (25.4x25.4x9.9 mm)
Copper
FR4 PCB
Silicon (UL94‐V0)
Six‐sided
UL60950‐1, IEC60950‐1, EN60950‐1
Class A, Class B
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
MECHANICAL DRAWING
SIDE VIEW
DIA.
0.04 (1.0)
1.00 (25.4)
0.800 (20.32)
PIN CONNECTIONS
PIN
SINGLE
DUAL
1
+INPUT
+INPUT
2
‐INPUT
‐INPUT
3
CTRL
CTRL
4
+OUTPUT
+OUTPUT
5
TRIM
COMMON
6
‐OUTPUT
‐OUTPUT
PRODUCT OPTIONS
OPTION
Positive Logic Remote On/Off
Negative Logic Remote On/Off
Without CTRL Pin
Without CTRL and TRIM Pins
Positive Logic without TRIM Pin
Negative Logic without TRIM Pin
Heatsink
SUFFIX
None
R
D
G
F
RF
HC
6
3
EXTERNAL OUTPUT TRIMMING
Output can be externally trimmed by using the
NOTES
method shown below
5
2
1. Unit: inches (mm)
2. Tolerance: X.XX±0.02 (X.X±0.5)
TRIM UP
TRIM DOWN
1
X.XXX±0.01 (X.XX±0.25)
6
5
4
BOTTOM
VIEW
3. Pin Pitch Tolerance: ±0.01 (±0.25)
RU
4. Pin Dimension Tolerance: ±0.004 (±0.1)
5. All dimensions are for reference only
5
RD
4
10/31/2014
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603‐778‐2300 • Toll Free: 888‐597‐9255 • Fax 603‐778‐9797
website: www.wallindustries.com • e‐mail: sales@wallindustries.com
Page 3 of 5