English
Language : 

PSGE50 Datasheet, PDF (2/5 Pages) Wall Industries,Inc. – AC/DC Switching Power Supplies
Rev. D
PSGE50 Series
Single Output
Up to 52.8 Watts
AC/DC Switching Power Supplies
SPECIFICATIONS: PSGE50 SERIES
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
INPUT SPECIFICATIONS
Input Voltage Range
Input Frequency
AC Current
Inrush Current
OUTPUT SPECIFICATIONS
Output Voltage
Output Power
Output Voltage Adjustability
Voltage Tolerance (see note 2)
Load Regulation (see note 3)
Line Regulation
Output Current
Ripple & Noise (see note 1)
Setup, Rise Time (see note 5)
Hold-Up Time
Temperature Coefficient
PROTECTION
Short Circuit Protection
Over Voltage Protection
Over Load Protection
Brown-Out Protection (Low AC Input Voltage)
GENERAL SPECIFICATIONS
Efficiency
Input to Output
Withstand Voltage
Input to FG
Output to FG
Isolation Resistance
Leakage Current
ENVIRONMENTAL SPECIFICATIONS
Working Temperature
Storage Temperature
Working Humidity
Storage Humidity
Vibration
Cooling
MTBF
PHYSICAL SPECIFICATIONS
Weight, Packing
Dimensions (L x W x H)
SAFETY & EMC (see note 6)
Safety Standards
EMI Conduction & Radiation
Harmonic Current
EMS Immunity
88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC surge for 5 seconds without damage)
50Hz / 60Hz
1.3A typ. at 115VAC; 0.5A typ. at 230VAC
Cold Start 40A typ. at 230VAC
See Table
See Table
±10%
3.3 VDC Output Model: ±3%
5 VDC Output Model: ±2%
12~48 VDC Output Models: ±1%
See Table
±0.5% (measured from low line to high line at full load)
See Table
See Table
1000ms, 80ms at 115VAC and full load
800ms, 80ms at 230VAC and full load
>10ms at 115VAC and full load; >32ms at 230VAC and full load
±0.03% / °C (0~50°C)
yes
115% ~ 150% rated output voltage
Protection type: latch-off mode
>110% rated output power
Protection Type: hiccup mode; recover automatically after fault condition is removed
yes
See Table
3000VAC (4242VDC) for 1 minute
1500VAC (2121VDC) for 1 minute
500VAC (707VDC) for 1 minute
100MΩ at 500VDC (input to output, input to FG, output to FG)
< 2mA at 240VAC
-25°C to +70°C (see derating curve)
-40°C to +85°C
20% to 90% RH (non-condensing)
10% to 95% RH
10 ~ 500Hz, 5G 10min/1cycle, period for 60 minutes each along X,Y,Z axes.
Free air convection
420,400 hours (Compliance: MIL-HDBK-217F)
9.88oz (280g); 45pcs/14kg
3.90 x 3.21 x 1.40 inches (99.0 x 81.5 x 35.5 mm)
UL60950-1, 2nd Edition, TUV EN60950-1: 2006+A11 Approved
EN55022: 1998+A1: 2000+A2: 2003 Class B
EN61000-3-2: 2000 Class A, EN61000-3-3: 1995+A1: 2001
EN61204-3: 2000, EN55024: 1998+A1: 2001+A2: 2003 light industry level, criteria A
01/08/2013
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797