English
Language : 

LANK10W Datasheet, PDF (2/8 Pages) Wall Industries,Inc. – 2:1 Wide Input Range Single and Dual Output 10 Watt DC/DC Converter
LANK 10W Series
2:1 Wide Input Range
Single and Dual Output
10 Watt DC/DC Converter
SPECIFICATION (CONTINUED)
ENVIRONMENTAL
Operating Temperature (Ambient)
Operating Temperature (Case)
Storage Temperature
Lead Temperature
Humidity
Cooling
MTBF
PHYSICAL
Weight
Dimensions
Case Material
TEST CONDITIONS
1.5mm from case for 10 seconds
MIL-HDBK-217F @ 25°C, Ground Benign
Min Nom Max Unit
-40
+60 °C
-40
+90 °C
-40
+125 °C
260 °C
95 %
Free air convection
1,000,000 Hours
17.3 grams
31.8(L) x 20.3(W) x 10.2(H) mm
Metal with non-conductive baseplate
OUTPUT VOLTAGE / CURRENT RATING CHART
Model Number
Input Voltage
Output
Voltage
Output Current
Min
Max
LANK1233W10
3.3 VDC 300mA 3000mA
LANK1205W10
5 VDC 200mA 2000mA
LANK1251W10
LANK1212W10
LANK1215W10
12 VDC
(9 – 18 VDC)
5.1 VDC
12 VDC
15 VDC
200mA
83mA
66.6mA
2000mA
833mA
666mA
LANK1212DW10
±12 VDC ±42mA ±416mA
LANK1215DW10
±15 VDC ±33mA ±333mA
LANK2425W10
2.5 VDC 300mA 3000mA
LANK2433W10
3.3 VDC 300mA 3000mA
LANK2405W10
5 VDC 200mA 2000mA
LANK2451W10
24 VDC
5.1 VDC 200mA 2000mA
LANK2412W10
(18 – 36 VDC) 12 VDC 83mA 833mA
LANK2415W10
15 VDC 66.6mA 666mA
LANK2412DW10
±12 VDC ±42mA ±416mA
LANK2415DW10
±15 VDC ±33mA ±333mA
LANK4825W10
2.5 VDC 300mA 3000mA
LANK4833W10
3.3 VDC 300mA 3000mA
LANK4805W10
LANK4851W10
48 VDC
5 VDC 200mA 2000mA
5.1 VDC 200mA 2000mA
LANK4812W10
(36 – 75 VDC) 12 VDC 83mA 833mA
LANK4815W10
15 VDC 66.6mA 666mA
LANK4812DW10
±12 VDC ±42mA ±416mA
LANK4815DW10
±15 VDC ±33mA ±333mA
Input Current (Typ)
No Load Max Load
1006mA
1004mA
1024mA
40mA 957mA
968mA
957mA
968mA
377mA
485mA
479mA
20mA
489mA
479mA
478mA
473mA
478mA
188mA
243mA
239mA
10mA
244mA
240mA
239mA
236mA
243mA
Reflected Ripple Efficiency
Current (Typ) (Typ)
82%
83%
83%
60mA
87%
86%
87%
86%
83%
85%
87%
40mA
87%
87%
87%
87%
87%
83%
85%
87%
40mA
87%
87%
87%
87%
87%
Max Capacitive
Load
2200µF
2200µF
2200µF
820µF
470µF
220µF
150µF
2200µF
2200µF
2200µF
2200µF
820µF
470µF
220µF
150µF
2200µF
2200µF
2200µF
2200µF
820µF
470µF
220µF
150µF
NOTES
1. Specifications typical at +25°C, resistive load, nominal input voltage, rated output current unless otherwise noted.
2. Transient Recovery Time is measured to within 1% error band for a step change in output of 75% to 100%.
3. Ripple and noise measured at 20MHz bandwidth.
4. The LANK 10W Series requires a minimum load on the output to maintain specified regulation. Operation under
no-load conditions will not damage these devices, however they may not meet all listed specifications.
5. All DC/DC converters should be externally fused on the front end for protection.
6. Other input and output voltages may be available, please contact factory.
7. Specifications subject to change without notice.
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797