English
Language : 

LANK10W Datasheet, PDF (1/8 Pages) Wall Industries,Inc. – 2:1 Wide Input Range Single and Dual Output 10 Watt DC/DC Converter
LANK 10W Series
2:1 Wide Input Range
Single and Dual Output
10 Watt DC/DC Converter
FEATURES
● I/O Isolation 1500VDC
● MTBF > 1,000,000 Hours
● Industry Standard Pinout
● High Efficiency up to 88%
● CSA1950 Safety Approval
● 2:1 Wide Input Voltage Range
● Complies with EN55022 Class A
● Short Circuit and Over Voltage Protection
SPECIFICATIONS: LANK 10W Series
All specifications are based on 25oC, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
TEST CONDITIONS
Min Nom Max Unit
INPUT (Vin)
12V input models
9
12
18 VDC
Input Voltage Range
24V input models
18
24
36 VDC
48V input models
36
48
75 VDC
12V input models
7
8
9
VDC
Start Voltage
24V input models
14
16
18 VDC
48V input models
30
33
36 VDC
12V input models
8.5 VDC
Under Voltage Shutdown
24V input models
17 VDC
48V input models
34 VDC
12V input models
-0.7
25 VDC
Input Surge Voltage (1000ms)
24V input models
-0.7
50 VDC
48V input models
-0.7
100 VDC
Reverse Polarity Input Current
All models
0.5 A
Reflected Ripple Current
See Table
Short Circuit Input Power
All models
2500 mW
Input Filter
All models
Pi Filter
OUTPUT (Vo)
Output Voltage Range
See Table
Output Voltage Accuracy
±0.6
±1.2 %
Output Voltage Balance
Dual Output, Balanced Loads
±0.5
±2.0 %
Load Regulation
Io = 10% to 100%
±0.5
±1.2 %
Load Regulation (2.5V output only)
Io = 10% to 100%
±0.7
±1.5 %
Line Regulation
Vin = Min to Max
±0.3
±1.0 %
Output Power
10 W
Output Current Range
See Table
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Over Line, Load, and Temperature
50
85
mVpk-pk
100
mVpk-pk
15 mVrms
Transient Recovery Time
25% Load Step Change
250
500 µs
Transient Response Deviation
25% Load Step Change
±3
±5 %
Temperature Coefficient
±0.01 ±0.02 %/°C
PROTECTION
Over Power Protection
110
150
180 %
Short Circuit Protection
Continuous
12V input models
2000mA Slow-Blow Type
Input Fuse Recommendation
24V input models
1000mA Slow-Blow Type
48V input models
500mA Slow-Blow Type
GENERAL
Efficiency
See Table
Switching Frequency
400
KHz
Isolation Voltage Rated
60 seconds
1500
VDC
Isolation Voltage Test
Flash Tested for 1 second
1650
VDC
Isolation Resistance
500VDC
1000
MΩ
Isolation Capacitance
100KHz, 1V
1000 1200 pF
Maximum Capacitive Load
See Table
Internal Power Dissipation
2500 mW
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797