English
Language : 

LANEUW Datasheet, PDF (2/9 Pages) Wall Industries,Inc. – Single and Dual Output 2 Watt DC/DC Converter 4:1 Ultra Wide Input Range
SPECIFICATION
ENVIRONMENTAL
Operating Temperature (Ambient)
Operating Temperature (Case)
Storage Temperature
Lead Temperature
Humidity
Cooling
MTBF
PHYSICAL
Weight
Dimensions
Case Material
TEST CONDITIONS
1.5mm from case for 10 seconds
MIL-HDBK-217F @ 25°C, Ground Benign
LANEUW Series
Single and Dual Output
2 Watt DC/DC Converter
4:1 Ultra Wide Input Range
Min Nom Max Unit
-40
+85 °C
-40
+90 °C
-55
+105 °C
260 °C
95 %
Free air convection
1,000,000 Hours
6.5 grams
25.95 x 9.25 x 12.45 mm
Non-conductive black plastic
OUTPUT VOLTAGE / CURRENT RATING CHART
Model Number
Input Voltage
Output
Voltage
Output Current
Min
Max
LANEUW2433R
3.3 VDC 125 mA 500 mA
LANEUW2405R
5 VDC 100 mA 400 mA
LANEUW2412R
LANEUW2415R
LANEUW2405RD
24 VDC
(9 – 36 VDC)
12 VDC
15 VDC
±5 VDC
42 mA
33 mA
±50 mA
167 mA
134 mA
±200 mA
LANEUW2412RD
±12 VDC ±21 mA ±83 mA
LANEUW2415RD
±15 VDC ±17 mA ±67 mA
LANEUW4833R
3.3 VDC 125 mA 500 mA
LANEUW4805R
5 VDC 100 mA 400 mA
LANEUW4812R
LANEUW4815R
48 VDC
(18 – 75 VDC)
12 VDC
15 VDC
42 mA
33 mA
167 mA
134 mA
LANEUW4805RD
±5 VDC ±50 mA ±200 mA
LANEUW4812RD
±12 VDC ±21 mA ±83 mA
LANEUW4815RD
±15 VDC ±17 mA ±67 mA
Input Current
Reflected Ripple Efficiency Max Capacitive
No Load Max Load
Current
(Typ)
Load
97 mA
71%
2200µF
110 mA
76%
1000µF
106 mA
79%
170µF
20 mA 105 mA 300 mA (Typ)
80%
110µF
114 mA
73%
470µF
108 mA
77%
100µF
106 mA
79%
47µF
49 mA
70%
2200µF
58 mA
72%
1000µF
54 mA
78%
170µF
15 mA
54 mA
600 mA (Typ)
78%
110µF
60 mA
70%
470µF
55 mA
76%
100µF
55 mA
76%
47µF
NOTES
1. Specifications typical at +25°C, resistive load, nominal input voltage, rated output current unless otherwise noted.
2. Transient Recovery Time is measured to within 1% error band for a step change in output of 75% to 100%.
3. Ripple and noise measured at 20MHz bandwidth.
4. The LANEUW Series requires a minimum load on the output to maintain specified regulation. Operation under
no-load conditions will not damage these devices, however they may not meet all listed specifications.
5. All DC/DC converters should be externally fused on the front end for protection.
6. Other input and output voltages may be available, please contact factory.
7. Specifications subject to change without notice.
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833