English
Language : 

ILPA35JUD Datasheet, PDF (1/2 Pages) Vitec Power – 35W Dimmable Water-Proof Constant Current LED Driver
ILPA35JUD SERIES
3 Year Warranty
35W Dimmable Water-Proof Constant Current LED Driver
– Wide Input Voltage 90 to 305VAC, 47 to 63Hz
– Dimming Control, Constant Current Output
– Over Voltage, Short Circuit, Lighting, and Over Temperature Protection
– High Efficiency (up to 88%)
– Active Power Factor Correction (PFC)
– IP67 Waterproof Rating, Metal Housing
– Comply with UL8750 & EN61347 Safety Regulation
Approvals:
Single Output
Part Number
Output Current Range
(Min. / Typ. / Max.)
Output Voltage Range
(Min. / Max.)
Efficiency
(220VAC, Full Load)
ILPA35JUD-S290DT
2755 / 2900 / 3045 mA
4 / 12 VDC
82%
ILPA35JUD-S245DT
2328 / 2450 / 2573 mA
5 / 15 VDC
83%
ILPA35JUD-S210DT
1995 / 2100 / 2205 mA
6 / 18 VDC
84%
ILPA35JUD-S175DT
1663 / 1750 / 1838 mA
7 / 20 VDC
84%
ILPA35JUD-S140DT
1330 / 1400 / 1470 mA
8 / 24 VDC
85%
ILPA35JUD-S105DT
998 / 1050 / 1103 mA
11 / 33 VDC
86%
ILPA35JUD-S070DT
665 / 700 / 735 mA
17 / 50 VDC
86%
ILPA35JUD-S045DT
428 / 450 / 473 mA
26 / 78 VDC
87%
ILPA35JUD-S035DT
333 / 350 / 368 mA
33 / 100 VDC
88%
Item -S290DT, -S245DT, -S210DT, -S175DT, -S140DT, -S105DT are Class 2 output (USR & CNR).
Item -S070DT is Class 2 output (USR), Non-Class 2 output (CNR)
Item -S045DT, -S035DT is Non-Class 2 output (USR & CNR)
Over Voltage Protection
(Min/Typ/Max)
13 / 15 / 17 VDC
16 / 18 / 20 VDC
19 / 21 / 23 VDC
23 / 25 / 27 VDC
30 / 32 / 34 VDC
39 / 41 / 43 VDC
57 / 58 / 59 VDC
95 / 97 / 99 VDC
118 / 120 / 122 VDC
Max.
Output Power
35W
35W
35W
35W
35W
35W
35W
35W
35W
Parameter
Input Voltage
Input Frequency
Output Power Range
Input Current (Low Line)
Input Current (High Line)
High Line Inrush Current
Power Factor Correction
Efficiency
No-Load Power Consumption
Line Regulation
Load Regulation
Over Voltage Protection
Over Temperature Protection
Short Circuit Protection
Output Overshoot / Undershoot
Start Up Time
Ripple & Noise (Peak to Peak)
Electrical Characteristics
Test Conditions
Min.
Typ.
Max.
Unit
Operating Voltage
90
305
VAC
47
63
Hz
Vin=90 to 264VAC
0
35
W
Io=Full load, Vin=115VAC
0.49
A
Io=Full load, Vin=230VAC
0.25
A
Io=Full load, 25°C, Cool start, Vin=230VAC
20
A
Vin=110VAC
92
%
Io=Full Load, Vin=230VAC
82
88
%
No Load, VIn=230VAC
6
W
Io=Full Load
2
%
Vin=230VAC
5
%
(Latch mode. The power unit shall return to normal operation only after the power is turn-on again.)
110
°C
No damage shall occur when any output operating in a short circuit condition. The power supply shall be
self-recovery when the fault condition is removed.
When power on or off
10
%
Io=Full Load, Vin=110VAC
1.7
2
S
Measured by 20 MHz bandwidth oscilloscope and the
output paralleled a 0.1 uF ceramic capacitor and a 10
10
% Vo
uF electrolytic capacitor.