TESTS AND REQUIREMENTS
Where applicable, all tests are carried out in accordance
with the following specifications:
EN 60115-1, generic specification
EN 60115-8 (successor of EN 140400), sectional
specification
EN 140401-803, detail specification
IEC 60068-2-xx, test methods
The parameters stated in the Test Procedures and
Requirements table are based on the required tests and
permitted limits of EN 140401-803, where applicable. The
table presents only the most important tests, for the full test
schedule refer to the documents listed above. However,
some additional tests and a number of improvements
against those minimum requirements have been included.
The testing also covers most of the requirements specified
by EIA/ECA-703 and JIS-C-5201-1.
The tests are carried out under standard atmospheric
conditions in accordance with IEC 60068-1, 4.3, whereupon
the following values are applied:
Temperature: 15 °C to 35 °C
Relative humidity: 25 % to 75 %
Air pressure: 86 kPa to 106 kPa (860 mbar to 1060 mbar).
A climatic category LCT / UCT / 56 is applied, defined by the
lower category temperature (LCT), the upper category
temperature (UCT), and the duration of exposure in the
damp heat, steady state test (56 days).
The components are mounted for testing on printed circuit
boards in accordance with EN 60115-8, 2.4.2, unless
otherwise specified.
TEST PROCEDURES AND REQUIREMENTS
EN
60 115-1
CLAUSE
IEC
60 068-2 (1)
TEST
METHOD
TEST
PROCEDURE
Stability for product types:
MMU 0102 HF
MMA 0204 HF
MMB 0207 HF
4.5
-
Resistance
MMU 0102 HF, MMB 0207 HF:
MMA 0204 HF:
4.8
-
Temperature coefficient
At (20 / -55 / 20) °C
and (20 / 125 / 20) °C
Endurance at 70 °C:
standard operation mode
U = P70 x R;
1.5 h on; 0.5 h off;
70 °C; 1000 h;
4.25.1
-
Endurance at 70 °C:
power operation mode
70 °C; 8000 h
U = P70 x R;
1.5 h on; 0.5 h off;
70°C; 1 000 h
70°C; 8 000 h
4.25.3
-
Endurance at upper category
temperature
125 °C; 1 000 h
155 °C; 1 000 h
4.24
78 (Cab)
Damp heat, steady state
(40 ± 2) °C; 56 days; (93 ± 3) % RH
4.23
Climatic sequence:
4.23.2
2 (Bb)
dry heat
UCT; 16 h
4.23.3
30 (Db)
damp heat, cyclic
55 °C; 24 h; 90 % RH; 1 cycle
4.23.4
1 (Ab)
cold
LCT; 2 h
4.23.5
13 (M)
low air pressure
8.5 kPa; 2 h; (25 ± 10) °C
4.23.6
30 (Db)
damp heat, cyclic
55 °C; 24 h;  90 % RH; 5 cycles
4.23.7
-
DC load
U = P70 x R ; 1 min.
LCT = -55 °C; UCT = 155 °C
-
1 (Aa)
Cold
-55 °C; 2 h
4.19
14 (Na) Rapid change of temperature
30 min at - 55 °C;
30 min at 155 °C; 5 cycles
REQUIREMENTS
PERMISSIBLE CHANGE (R)
6.8  to 470 
1.5  to 475 
6.8  to 470 
±2%R
±1%R
± 50 ppm/K
± (0.25 % R + 0.05 )
± (0.5 % R + 0.05 )
± (0.5 % R + 0.05 )
± (1 % R + 0.05 )
± (0.5 % R + 0.05 )
± (1 % R + 0.05 )
± (0.5 % R + 0.05 )
± (0.5 % R + 0.05 )
± (0.1 % R + 0.01 )
± (0.25 % R + 0.05 )