DG611A Datasheet, PDF (6/11 Pages) Vishay Siliconix – 1 pC Charge Injection, 100 pA Leakage, Quad SPST Switches
DG611A/DG612A/DG613A
Vishay Siliconix
New Product
SPECIFICATIONS FOR UNIPOLAR SUPPLIES V+ = + 3 V, V- = 0 V
Parameter
Analog Switch
Symbol
Test Conditions
Unless Specified
V+ = + 3 V, V- = 0 V
VIN = 1.4 V, 0.6 Va
- 40 to 125 °C
Temp.b Typ.c Min.d Max.d
Analog Signal Rangee
On-Resistance
VANALOG
rON
IS = 1 mA, VD = + 1.5 V
Full
Room 195
Full
0
3
235
300
Switch Off
Leakage Current
IS(off)
ID(off)
V+ = 3.3 V, V- = 0 V
VD = 3 V/0.3 V
VS = 0.3 V/3 V
Room ± 0.02 - 0.1 0.1
Full
-2
2
Room ± 0.02 - 0.1 0.1
Full
-2
2
Switch On
Leakage Current
Digital Control
ID(on)
V+ = 3.3 V, V- = 0 V
VD = VS = 0.3 V/3 V
Room ± 0.02 - 0.1 0.1
Full
-6
6
Input Current, VIN Low
IIL
VIN Under Test = 0.6 V
Full 0.005 - 0.1 0.1
Input Current, VIN High
IIH
Input Capacitancee
CIN
Dynamic Characteristics
VIN Under Test = 1.4 V
f = 1 MHz
Full 0.005 - 0.1 0.1
Room
2
Turn-On Time
Turn-Off Time
tON
Room
87
RL = 300 Ω, CL = 35 pF
Full
125
180
tOFF
VS = 2 V, see Figure 1
Room
33
Full
55
65
Break-Before-Make
Time Delay
Charge Injectione
Off Isolatione
Channel-to-Channel
Crosstalke
tBBM
DG613 only, VS = 2 V
Room
60
RL = 300 Ω, CL = 35 pF
Full
10
Q
Vg = 0 V, Rg = 0 Ω, CL = 1 nF Room
2.3
OIRR
XTALK
RL = 50 Ω, CL = 5 pF
f = 10 MHz
Room - 60
Room - 90
3 dB Bandwidthe
Source Off Capacitancee
Drain Off Capacitancee
BW
CS(off)
CD(off)
RL = 50 Ω, CL = 5 pF
f = 1 MHz; VS = 0 V
Room 550
Room
5
Room
6
Drain On Capacitancee
Power Supplies
CD(on)
f = 1 MHz; VS = VD = 0 V Room
9
Power Supply Current
I+
Room 0.001
0.1
Full
1
Negative Supply Current
I-
VIN = 0 or 3 V
Room - 0.001 - 0.1
Full
-1
Ground Current
IGND
Room - 0.001 - 0.1
Full
-1
- 40 to 85 °C
Min.d Max.d
0
3
235
280
- 0.1 0.1
- 0.25 0.25
- 0.1 0.1
- 0.25 0.25
- 0.1 0.1
- 0.25 0.25
- 0.1 0.1
- 0.1 0.1
125
170
55
60
10
0.1
1
- 0.1
-1
- 0.1
-1
Unit
V
Ω
nA
µA
pF
ns
pC
dB
MHz
pF
µA
Notes:
a. VIN = input voltage to perform proper function.
b. Room = 25 °C, Full = as determined by the operating temperature suffix.
c. Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
d. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
e. Guaranteed by design, not subject to production test.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation
of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
www.vishay.com
6
Document Number: 69904
S-72760-Rev. A, 04-Feb-08