English
Language : 

VS-MBRS320TRPBF Datasheet, PDF (4/7 Pages) Vishay Siliconix – Very low forward voltage drop
VS-MBRS320TRPbF
Vishay High Power Products Schottky Rectifier, 3.0 A
155
150
145
140
135
130 Square wave
D = 0.20
D = 0.25
D = 0.33
D = 0.50
D = 0.75
DC
125 See note (1)
120
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5
IF(AV) - Average Forward Current (A)
Fig. 5 - Maximum Average Forward Current vs.
Allowable Lead Temperature
1.6
D = 0.20
1.4
D = 0.25
D = 0.33
1.2
D = 0.50
D = 0.75
1.0
RMS limit
0.8
0.6
0.4
DC
0.2
0
0
1
2
3
4
5
IF(AV) - Average Forward Current (A)
Fig. 6 - Maximum Average Forward Dissipation vs.
Average Forward Current
1000
TJ = 25 °C
100
At any rated load condition
and with rated VRRM applied
following surge
10
10
100
1000
10 000
tp - Square Wave Pulse Duration (µs)
Fig. 7 - Maximum Peak Surge Forward Current vs.
Pulse Duration
Note
(1) Formula used: TC = TJ - (Pd + PdREV) x RthJC;
Pd = Forward power loss = IF(AV) x VFM at (IF(AV)/D) (see fig. 6);
PdREV = Inverse power loss = VR1 x IR (1 - D)
www.vishay.com
4
For technical questions, contact: diodestech@vishay.com
Document Number: 94320
Revision: 05-Mar-10