English
Language : 

DG535_08 Datasheet, PDF (4/12 Pages) Vishay Siliconix – 16-Channel Wideband Video Multiplexers
DG535/536
Vishay Siliconix
SPECIFICATIONSa
Parameter
Symbol
Test Conditions
Unless Otherwise Specified
V+ = 15 V, ST, CS = 10.5 V
CS = 4.5 V, VA = 4.5 or 10.5 Vf
A Suffix
D Suffix
- 55 to 125 °C - 40 to 85 °C
Tempb Typc Minc Maxc Minc Maxc Unit
Power Supplies
Positive Supply Current
Supply Voltage Range
I+
Room 5
Any One Channge I Selected with All Full
50
100
50
100
µA
Logic Inputs at GND or V+
V+
Full
10 16.5 10 16.5 V
Minimum Input Timing Requirements
Strobe Pulse Width
tSW
Full
200
200
A0, A1, A2, A3 CS, CS, EN
Data Valid to Strobe
tDW
See Figure 1
Full
100
100
ns
A0, A1, A2, A3 CS, CS, EN
Data Valid after Strobe
tWD
Full
50
50
Notes:
a. Refer to PROCESS OPTION FLOWCHART.
b. Room = 25 °C, Full = as determined by the operating temperature suffix.
c. Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
d. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
e. Guaranteed by design, not subject to production test.
f. VA = input voltage to perform proper function.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation
of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
TYPICAL CHARACTERISTICS 25 °C, unless otherwise noted
400
360
V+ = +15 V
GND = 0 V
320
280
240
125 °C
200
160
120
25 °C
80
40
- 55 °C
0
0
2
4
6
8
10
VD – Drain Voltage (V)
rDS(on) vs. VD and Temperature
300
270
GND = 0 V
TA = 25 °C
240
210
8V
180
12 V
150
15 V
120
90
60
30
0
0
2
4
6
8
10
VD – Drain Voltage (V)
rDS(on) vs. VD and Power Supply Voltage
www.vishay.com
4
Document Number: 70070
S-71241–Rev. E, 25-Jun-07