English
Language : 

DG451 Datasheet, PDF (4/9 Pages) Vishay Siliconix – High Voltage 4-Ω Quad SPST CMOS Analog Switch
DG451/DG452/DG453
Vishay Siliconix
New Product
SPECIFICATIONS FOR DUAL SUPPLIES
Parameter
Power Supplies
Symbol
Test Conditions
Unless Specified
V+ = 5 V, V- = - 5 V
VL = 5 V, VIN = 2.4 V, 0.8 Va
Power Supply Current
I+
Negative Supply Current
Logic Supply Current
Ground Current
I-
IL
IGND
VL = 5 V, VIN = 0 or 5 V
- 40 to 125 °C - 40 to 85 °C
Temp.b Typ.c Min.d Max.d Min.d Max.d Unit
Room 0.001
Full
- 0.5
-5
- 0.5
-5
Room - 0.001 - 0.5
- 0.5
Full
Room
0.001
-5
- 0.5
-5
µA
- 0.5
Full
-5
-5
Room - 0.001 - 0.5
Full
-5
- 0.5
-5
SPECIFICATIONS FOR UNIPOLAR SUPPLIES
Parameter
Analog Switch
Symbol
Test Conditions
Unless Specified
V+ = 12 V, V- = 0 V
VL = 5 V, VIN = 2.4 V, 0.8 Va
Temp.b
Analog Signal Rangee
VANALOG
Full
On-Resistance
RON
IS = - 10 mA, VD = 0 V to + 10 V
Room
Full
On-Resistance Match
ΔRON
IS = - 10 mA, VD = + 10 V
Room
Full
On-Resistance Flatness
Dynamic Characteristics
RFLATNESS
IS = - 10 mA,
VD = 0 V, + 5 V, + 10 V
Room
Full
Turn-On Time
Turn-Off Time
tON
RL = 300 Ω, CL = 35 pF
Room
Full
tOFF
VS = 8 V, See Figure 2
Room
Full
Break-Before-Make
Time Delay
Charge Injectione
Power Supplies
tD
DG453 only, VS = 8 V
RL = 300 Ω, CL = 35 pF
Room
Q
Vg = 0 V, Rg = 0 Ω, CL = 1 nF Room
Power Supply Current
I+
Room
Full
Negative Supply Current
Logic Supply Current
I-
Room
Full
IL
VL = 5 V, VIN = 0 or 5 V
Room
Full
Ground Current
IGND
Room
Full
Typ.c
5.5
0.14
0.94
132
61
70
1
0.001
- 0.001
0.001
- 0.001
- 40 to 125 °C - 40 to 85 °C
Min.d Max.d Min.d Max.d Unit
12
12
V
8.1
8.1
12.4
10.4
0.5
1
0.5
0.5
Ω
1.5
1.5
1.7
1.5
162
162
238
210
91
117
91
105
ns
pC
0.5
0.5
5
5
- 0.5
- 0.5
-5
-5
µA
0.5
0.5
5
5
- 0.5
-5
- 0.5
-5
Notes:
a. VIN = input voltage to perform proper function.
b. Room = 25 °C, Full = as determined by the operating temperature suffix.
c. Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
d. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
e. Guaranteed by design, not subject to production test.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation
of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
www.vishay.com
4
Document Number: 74470
S-81306-Rev. D, 09-Jun-08