English
Language : 

ILD620GB-X009T Datasheet, PDF (3/9 Pages) Vishay Siliconix – Optocoupler, Phototransistor Output, AC Input (Dual, Quad Channel)
www.vishay.com
ILD620, ILD620GB, ILQ620, ILQ620GB
Vishay Semiconductors
ELECTRICAL CHARACTERISTICS (Tamb = 25 °C, unless otherwise specified)
PARAMETER
TEST CONDITION
PART
SYMBOL MIN. TYP. MAX. UNIT
COUPLER
Off-state collector current
Collector emitter saturation voltage
VF = ± 0.7 V, VCE = 24 V
IF = ± 8 mA, ICE = 2.4 mA
IF = ± 1 mA, ICE = 0.2 mA
ILD620
ILQ620
ILD620GB
ILQ620GB
ICEoff
VCEsat
VCEsat
VCEsat
VCEsat
1
10
μA
0.4
V
0.4
V
0.4
V
0.4
V
Note
• Minimum and maximum values are testing requirements. Typical values are characteristics of the device and are the result of engineering
evaluation. Typical values are for information only and are not part of the testing requirements.
CURRENT TRANSFER RATIO (Tamb = 25 °C, unless otherwise specified)
PARAMETER
TEST CONDITION
PART
SYMBOL
Channel/channel CTR match
CTR symmetry
Current transfer ratio 
(collector emitter saturated)
Current transfer ratio 
(collector emitter)
Current transfer ratio 
(collector emitter saturated)
Current transfer ratio 
(collector emitter)
IF = ± 5 mA, VCE = 5 V
ICE (IF = - 5 mA)/ICE (IF = + 5 mA)
IF = ± 1 mA, VCE = 0.4 V
IF = ± 5 mA, VCE = 5 V
IF = ± 1 mA, VCE = 0.4 V
IF = ± 5 mA, VCE = 5 V
ILD620
ILQ620
ILD620
ILQ620
ILD620GB
ILQ620GB
ILD620GB
ILQ620GB
CTRX/CTRY
ICE(RATIO)
CTRCEsat
CTRCEsat
CTRCE
CTRCE
CTRCEsat
CTRCEsat
CTRCEsat
CTRCEsat
MIN.
1 to 1
0.5
50
50
30
30
100
100
TYP.
60
60
80
80
200
200
MAX.
3 to 1
2
600
600
600
600
UNIT
%
%
%
%
%
%
%
%
SAFETY AND INSULATION RATED PARAMETERS
PARAMETER
TEST CONDITION
SYMBOL
MIN.
TYP.
MAX.
UNIT
Partial discharge test voltage -
routine test
100 %, ttest = 1 s
Vpd
1.669
kV
Partial discharge test voltage -
tTr = 60 s, ttest = 10 s,
VIOTM
10
kV
lot test (sample test)
(see figure 2)
Vpd
1.424
kV
VIO = 500 V
RIO
1012

Insulation resistance
VIO = 500 V, Tamb = 100 °C
RIO
1011

VIO = 500 V, Tamb  150 °C
(construction test only)
RIO
109

Forward current
Power dissipation
Rated impulse voltage
Safety temperature
Isi
PSO
VIOTM
Tsi
275
mA
400
mW
10
kV
175
°C
Note
• According to DIN EN 60747-5-5 (VDE 0884) (see figure 2). This optocoupler is suitable for safe electrical isolation only within the safety
ratings. Compliance with the safety ratings shall be ensured by means of suitable protective circuits.
Rev. 1.8, 12-Apr-13
3
Document Number: 83653
For technical questions, contact: optocoupleranswers@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000