English
Language : 

DG444_11 Datasheet, PDF (3/12 Pages) Vishay Siliconix – Quad SPST CMOS Analog Switches
SPECIFICATIONS for Dual Supplies
Parameter
Power Supplies
Positive Supply Current
Negative Supply Current
Logic Supply Current
Ground Current
Symbol
I+
I-
IL
IGND
Test Conditions
Unless Otherwise Specified
V+ = 15 V, V- = - 15 V
VL = 5 V, VIN = 2.4 V, 0.8 Ve
V+ = 16.5 V, V- = - 16.5 V
VIN = 0 or 5 V
DG444, DG445
Vishay Siliconix
D Suffix
- 40 °C °C to 85 °C
Temp.a Min.b Typ.c Max.b Unit
Room
Full
0.001
1
5
Room - 1 - 0.0001
Full
-5
µA
Room
Full
0.001
1
5
Room
Full
-1
-5
- 0.001
SPECIFICATIONS for Unipolar Supplies
Parameter
Analog Switch
Symbol
Test Conditions
Unless Otherwise Specified
V+ = 12 V, V- = 0 V
VL = 5 V, VIN = 2.4 V, 0.8 Ve
Limits
- 40 °C °C to 85 °C
Temp.a Min.b Typ.c Max.b Unit
Analog Signal Ranged
Drain-Source
On-Resistanced
Dynamic Characteristics
VANALOG
RDS(on)
IS = - 10 mA, VD = 3 V, 8 V
V+ = 10.8 V, VL = 5.25 V
Full
0
Room
Full
12
V
100
160
200

Turn-On Time
Turn-Off Time
Charge Injection
Power Supplies
tON
RL = 1 k, CL = 35 pF, VS = 8 V
Room
tOFF
See Figure 2
Room
Q
CL = 1 nF, Vgen = 6 V, Rgen = 0 
Room
300
450
ns
60
200
2
pC
Positive Supply Current
Negative Supply Current
Logic Supply Current
Ground Current
I+
I-
IL
IGND
V+ = 13.2 V, VIN = 0 or 5 V
VIN = 0 or 5 V
VL = 5.25 V, VIN = 0 or 5 V
VIN = 0 or 5 V
Room
0.001
1
Full
5
Room - 1 - 0.0001
Full
-5
µA
Room
0.001
1
Full
5
Full
- 1 - 0.001
-5
Notes:
a. Room = 25 °C, Full = as determined by the operating temperature suffix.
b. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this datasheet.
c. Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
d. Guaranteed by design, not subject to production test.
e. VIN = input voltage to perform proper function.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation
of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
Document Number: 70054
www.vishay.com
S11-0984-Rev. G, 23-May-11
3
This document is subject to change without notice.
THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000