English
Language : 

DG2717 Datasheet, PDF (3/8 Pages) Vishay Siliconix – Low-Voltage, 0.45-Ω, SPDT Analog Switch
DG2717
Vishay Siliconix
SPECIFICATIONS (V+ = 3.0 V)
Parameter
Analog Switch
Analog Signal Ranged
On-Resistance
rON Flatnessd
rON Matchd
Switch Off Leakage Current
Symbol
Test Condition
Otherwise Unless Specified
V+ = 2.7 V to 3.6 V, VIN = 0.5 or 1.4 Ve
Tempa
Limits
- 40 to 85 °C
Minb Typc Maxb
Unit
VNO, VNC,
VCOM
Full
0
V+
V
rON
rON
Flatness
V+ = 2.7 V, VCOM = 1.5 V
INO, INC = 100 mA
V+ = 3.6 V, VCOM = 0.5 V, 2.0 V
INO, INC = 100 mA
V+ = 2.7 V, VCOM = 0.6 V, 2.1 V
INO, INC = 100 mA
Room
Full
Room
Full
Room
0.5
0.7
0.8
0.45 0.65
0.75
Ω
0.2
ΔrON V+ = 2.7 V, VCOM = 1.5 V, INO, INC = 100 mA Room
0.6
INO(off),
INC(off)
ICOM(off)
V+ = 4.3 V
VNO, VNC = 0.3 V / 4 V, VCOM = 4 V / 0.3 V
Room
Full
Room
Full
- 10
- 100
- 10
- 100
10
100
10
nA
100
Channel-On Leakage Current
ICOM(on)
V+ = 4.3 V, VNO, VNC = VCOM = 0.3 V / 4 V
Room
Full
- 10
- 100
10
100
Digital Control
Input High Voltage
Input Low Voltage
Input Capacitanced
Input Currentf
Dynamic Characteristics
VINH
VINL
Cin
IINL or IINH
VIN = 0 V or V+
Full
1.4
Full
V
0.5
Full
7
pF
Full
-1
1
µA
Turn-On Time
Turn-Off Time
Break-Before-Make Time
Charge Injectiond
Off-Isolationd
Crosstalkd
NO, NC Off Capacitanced
Channel-On Capacitanced
Power Supply
tON
V+ = 3.0 V, VNO or VNC = 1.5 V
Room
Full
22
44
48
tOFF
RL = 300 Ω, CL = 35 pF
Figure 1 and 2
Room
Full
8
29
ns
30
td
Room
1
QINJ
CL = 1 nF, VGEN = 0 V, RGEN = 0 Ω, Figure 3 Room
28
pC
OIRR
XTALK
RL = 50 Ω, CL = 5 pF, f = 1 MHz
Room
Room
- 54
- 57
dB
CNO(off),
CNC(off)
VIN = 0 or V+, f = 1 MHz
Room
76
pF
CON
Room
178
Power Supply Range
V+
Power Supply Current
I+
V+ = 3.6 V, VIN = 0 or V+
1.6
4.3
V
0.01
1.0
µA
Notes:
a. Room = 25 °C, Full = as determined by the operating suffix.
b. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
c. Typical values are for design aid only, not guaranteed nor subject to production testing.
d. Guarantee by design, nor subjected to production test.
e. VIN = input voltage to perform proper function.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation
of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
Document Number: 73538
S-70852-Rev. B, 30-Apr-07
www.vishay.com
3