English
Language : 

DG2511_11 Datasheet, PDF (3/9 Pages) Vishay Siliconix – Low-Voltage, Low RON, Single Analog Switch In miniQFN-6 Package
DG2511, DG2512, DG2513
Vishay Siliconix
SPECIFICATIONS (V+ = 5 V)
Parameter
Symbol
Test Conditions
Otherwise Unless Specified
V+ = 5 V, ± 10 %, VIN = 0.6 V or 1.8 Ve
Temp.a
Limits
- 40 °C to 85 °C
Min.b Typ.c Max.b
Unit
Analog Switch
Analog Signal Ranged
On-Resistance
RON Match
RON Flatness
VNO, VNC,
VCOM
RON
RON
RON
Flatness
V+ = 4.5 V, VCOM = 0.5 V/2.5 V,
INO, INC = 100 mA
Full
0
Room
Full
Room
Room
V+
V
1
1.3
1.45
0.15 
0.3
0.4
Switch Off Leakage Current
INO(off)
INC(off)
ICOM(off)
V+ = 5.5 V,
VNO, VNC= 1 V/4.5 V, VCOM = 4.5 V/1 V
Room - 2
Full
- 20
Room - 2
Full
- 20
2
20
2
nA
20
Channel-On Leakage Current
ICOM(on)
V+ = 5.5 V, VNO, VNC = VCOM = 1 V/4.5 V
Room - 2
Full
- 20
2
20
Digital Control
Input High Voltage
Input Low Voltage
Input Capacitance
Input Current
VINH
VINL
Cin
IINL or IINH
VIN = 0 or V+
Full
1.8
Full
V
0.6
Full
4
pF
Full
1
1
µA
Dynamic Characteristics
Turn-On Time
Turn-Off Time
Break-Before-Make Time
Charge Injectiond
Off-Isolationd
Crosstalkd
NO, NC Off Capacitanced
Channel-On Capacitanced
tON
Room
Full
tOFF
VNO or VNC = 2.5 V, RL = 50 , CL = 35 pF
Room
Full
tBBM
QINJ
CL = 1 nF, VGEN = 0 V, RGEN = 0 
Room
1
Room
OIRR
XTALK
RL = 50, CL = 5 pF, f = 1 MHz
Room
Room
CNO(off)
CNC(off)
CON
VIN = 0 or V+, f = 1 MHz
Room
Room
11
35
39
6
31
ns
33
5
14
pC
- 58
dB
- 64
19
pF
61
Power Supply
Power Supply Range
V+
Power Supply Current
I+
VIN = 0 or V+
1.8
5.5
V
0.01
1
µA
Notes:
a. Room = 25 °C, Full = as determined by the operating suffix.
b. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this datasheet.
c. Typical values are for design aid only, not guaranteed nor subject to production testing.
d. Guarantee by design, nor subjected to production test.
e. VIN = input voltage to perform proper function.
f. Guaranteed by 5 V leakage testing, not production tested.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation
of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
Document Number: 74454
www.vishay.com
S11-0984–Rev. C, 23-May-11
3
This document is subject to change without notice.
THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000