ABSOLUTE MAXIMUM RATINGS (Tamb = 25 °C, unless otherwise specified)
PARAMETER
TEST CONDITION
SYMBOL
VALUE
UNIT
INPUT
Reverse voltage
Forward current
Forward surge current
Power dissipation
Junction temperature
OUTPUT
tp ≤ 10 μs
VR
6
V
IF
60
mA
IFSM
1.5
A
Pdiss
100
mW
Tj
125
°C
Collector emitter voltage
Emitter collector voltage
Collector current
Collector peak current
Power dissipation
Junction temperature
COUPLER
VCEO
70
V
VECO
7
V
IC
50
mA
tp/T = 0.5, tp ≤ 10 ms
ICM
100
mA
Pdiss
150
mW
Tj
125
°C
AC isolation test voltage (RMS)
Related to standard climate 23/50
DIN 50014
VISO
3750
VRMS
Total power dissipation
Operating ambient temperature range
Storage temperature range
Soldering temperature (1)
Ptot
250
mW
Tamb
- 40 to + 100
°C
Tstg
- 40 to + 125
°C
Tsld
260
°C
Notes
• Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. Functional operation of the device is not
implied at these or any other conditions in excess of those given in the operational sections of this document. Exposure to absolute
maximum ratings for extended periods of the time can adversely affect reliability.
(1) Refer to reflow profile for soldering conditions for surface mounted devices. Also refer to “Assembly Instructions”
(www.vishay.com/doc?80054).
ELECTRICAL CHARACTERISTICS (Tamb = 25 °C, unless otherwise specified)
PARAMETER
TEST CONDITION
SYMBOL
MIN.
TYP.
MAX.
UNIT
INPUT
Forward voltage
Junction capacitance
OUTPUT
IF = 50 mA
VF
VR = 0, f = 1 MHz
Cj
1.35
1.6
V
8
pF
Collector emitter voltage
Emitter collector voltage
Collector dark current
COUPLER
IC = 100 μA
VCEO
70
IE = 100 μA
VECO
7
VCE = 20 V, IF = 0 A
ICEO
V
V
100
nA
Collector emitter saturation voltage
Cut-off frequency
Coupling capacitance
IF = 10 mA, IC = 1 mA
VCE = 5 V, IF = 10 mA,
RL = 100 Ω
f = 1 MHz
VCEsat
fc
Ck
0.3
V
100
kHz
0.3
pF
Note
• Minimum and maximum values are testing requirements. Typical values are characteristics of the device and are the result of engineering
evaluation. Typical values are for information only and are not part of the testing requirements.
Rev. 3.0, 10-Mar-16
2
Document Number: 83510
For technical questions, contact: optocoupleranswers@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000