SPECIFICATIONS TJ = 25 °C, unless otherwise noted
Parameter
Symbol
Test Conditions
Static
Drain-Source Breakdown Voltage
VDS
VDS = 0 V, ID = 250 µA
Gate Threshold Voltage
VGS(th)
VDS = VGS, ID = 250 µA
Gate-Body Leakage
IGSS
VDS = 0 V, VGS = ± 20 V
VDS = 60 V, VGS = 0 V
Zero Gate Voltage Drain Current
IDSS
VDS = 60 V, VGS = 0 V, TJ = 125 °C
On-State Drain Currenta
ID(on)
VDS = 60 V, VGS = 0 V, TJ = 150 °C
VDS 10 V, VGS = 10 V
Drain-Source On-State Resistancea
Forward Transconductancea
Dynamicb
RDS(on)
gfs
VGS = 10 V, ID = 30 A
VGS = 10 V, ID = 30 A, TJ = 125 °C
VDS = 15 V, ID = 15 A
Input Capacitance
Ciss
Output Capacitance
Coss
VGS = 0 V, VDS = 30 V, f = 1 MHz
Reverse Transfer Capacitance
Total Gate Chargec
Gate-Source Chargec
Gate-Drain Chargec
Crss
Qg
Qgs
VDS = 30 V, VGS = 10 V, ID = 20 A
Qgd
Gate Resistance
Turn-On Delay Timec
Rise Timec
Turn-Off Delay Timec
Fall Timec
Rg
td(on)
tr
td(off)
tf
f = 1 MHz
VDD = 30 V, RL = 1.53 
ID  20 A, VGEN = 10 V, Rg = 1 
Source-Drain Diode Ratings and Characteristics TC = 25 °Cb
Continuous Current
IS
Pulsed Current
Forward Voltagea
ISM
VSD
IF = 10 A, VGS = 0 V
Reverse Recovery Time
trr
Peak Reverse Recovery Current
IRM(REC)
IF = 10 A, dI/dt = 100 A/µs
Reverse Recovery Charge
Qrr
Notes:
a. Pulse test; pulse width  300 µs, duty cycle  2 %.
b. Guaranteed by design, not subject to production testing.
c. Independent of operating temperature.
Min.
Typ.
Max.
Unit
60
V
2.5
4.5
± 250
nA
1
50
µA
250
80
A
0.0098 0.012

0.0155 0.019
37
S
1970
310
pF
110
33
55
11
nC
9
0.3
1.4
2.8

11
20
11
20
ns
16
30
8
15
60
A
80
0.84
1.5
V
40
80
ns
3.2
5.0
A
64
120
nC
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation
of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
www.vishay.com
2
Document Number: 69070
S10-1475-Rev. C, 05-Jul-10