English
Language : 

SI9138 Datasheet, PDF (2/14 Pages) Vishay Siliconix – Multi-Output, Individual On/Off Control Power-Supply Controller
Si9138
Vishay Siliconix
New Product
ABSOLUTE MAXIMUM RATINGS
VIN to GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 to +36 V
PGND to GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±2 V
VL to GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 to +6.5 V
BST3, BST5, BSTFY to GND . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +36 V
VL Short to GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Continuous
LX3 to BST3; LX5 to BST5; LXFY to BSTFY . . . . . . . . . . . . . . . –6.5 V to 0.3 V
Inputs/Outputs to GND
(CS3, CS5, CSP, CSN) . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to (VL +0.3 V)
RESET, ON3, ON5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +5.5 V
DL3, DL5, DLFY to PGND . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to (VL +0.3 V)
DH3 to LX3, DH5 to LX5,
DHFY to LXFY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to (BSTx +0.3 V)
Continuous Power Dissipation (TA = 70_C)a
28-Pin SSOPb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 762 mW
Operating Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0_C to 90_C
Storage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . –40_C to 125_C
Lead Temperature (Soldering, 10 Sec.) . . . . . . . . . . . . . . . . . . . . . . . . . . 300_C
Notes
a. Device mounted with all leads soldered or welded to PC board.
b. Derate 9.52 mW/_C above 70_C.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation
of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
SPECIFICATIONS
Parameter
3.3-V Buck Controller
Total Regulation (Line, Load, and Temperature)
Line Regulation
Load Regulation
Current Limit
Bandwidth
Phase Margin
5-V Buck Controller
Total Regulation (Line, Load, and Temperature)
Line Regulation
Load Regulation
Current Limit
Bandwidth
Phase Margin
5- to 12-V Buck-Boost Controller
Total Regulation (Line, Load, and Temperature)
Output Voltage Set to 12 V
Line Regulation
Load Regulation
Current Limit
Bandwidth
Phase Margin
Internal Regulator
VL Output
VL Fault Lockout Voltage
VL Fault Lockout Hysteresis
VL /FB5 Switchover Voltage
VL /FB5 Switchover Hysteresis
www.vishay.com
2
Test Conditions
VIN = 15 V , IVL = IREF = 0 mA
TA = 0_C to 90_C, All Controllers ON
VIN = 6 to 30 V, 0 < VCS3 – VFB3 < 90 mV
VIN = 6 to 30 V
0 < VCS3 – VFB3 < 90 mV
VCS3 – VFB3
L = 10 mH, C = 330 mF
RSENSE = 20 mW
VIN = 6 to 30 V, 0 < VCS5 – VFB5 < 90 mV
VIN = 6 to 30 V
0 < VCS5 – VFB5 < 90 mV
VCS5 – VFB5
L = 10 mH, C = 330 mF
RSENSE = 20 mW
VIN = 6 to 30 V, 0 < VCSP – VCSN < 300 mV
R5 = 26.4 kW, R6 = 10 kW (See Figure 1)
VIN = 6 to 30 V
0 < VCSP – VFBN < 300 mV
VCSP – VCSN
L = 10 mH, C = 100 mF
RSENSE = 100 mW, Ccomp = 120 pF
All Controllers OFF, VIN >5.5 V, 0 <IL <30 mA
VL Falling Edge
FB5 Rising Edge
Mina
Limits
Typb
Maxa
Unit
3.22
3.32
3.42
V
±0.5
%
±0.5
90
125
160
mV
50
kHz
65
_
4.87
5.02
5.17
V
±0.5
%
±0.5
90
125
160
mV
50
kHz
65
_
11.4
12.0
12.6
V
±0.5
%
±0.5
330
410
500
mV
10
kHz
65
_
4.7
5.5
V
3.6
4.2
75
mV
4.2
4.7
V
75
mV
Document Number: 71446
S-20642—Rev. B, 13-May-02