SPECIFICATIONS TJ = 25 °C, unless otherwise noted
Parameter
Symbol
Test Conditions
Static
Drain-Source Breakdown Voltage
VDS
VGS = 0 V, ID = 1 mA
Gate-Source Threshold Voltage
VGS(th)
VDS = VGS, ID= 1 mA
Gate-Source Leakage
IGSS
VDS = 0 V, VGS = ± 20 V
Zero Gate Voltage Drain Current
IDSS
VDS = 30 V, VGS = 0 V
VDS = 30 V, VGS = 0 V, TJ = 100 °C
On -State Drain Currenta
ID(on)
VDS ≥ 5 V, VGS = 10 V
Drain-Source On-State Resistancea
RDS(on)
VGS = 10 V, ID = 10 A
VGS = 4.5 V, ID = 7 A
Forward Transconductancea
Dynamicb
gfs
VDS = 15 V, ID = 10 A
Input Capacitance
Ciss
Output Capacitance
Coss
VDS = 15 V, VGS = 0 V, f = 1 MHz
Reverse Transfer Capacitance
Crss
Total Gate Charge
Qg
VDS = 15 V, VGS = 10 V, ID = 10 A
Gate-Source Charge
Gate-Drain Charge
Qgs
VDS = 15 V, VGS = 4.5 V, ID = 10 A
Qgd
Gate Resistance
Rg
f = 1 MHz
Turn-On Delay Time
td(on)
Rise Time
Turn-Off Delay Time
tr
td(off)
VDD = 15 V, RL = 1.5 Ω
ID ≅ 10 A, VGEN = 4.5 V, Rg = 1 Ω
Fall Time
tf
Turn-On Delay Time
td(on)
Rise Time
Turn-Off Delay Time
tr
td(off)
VDD = 15 V, RL = 1.5 Ω
ID ≅ 10 A, VGEN = 10 V, Rg = 1 Ω
Fall Time
tf
Drain-Source Body Diode and Schottky Characteristics
Continuous Source-Drain Diode Current
IS
TC = 25 °C
Pulse Diode Forward Currenta
ISM
Body Diode Voltage
VSD
IS = 2 A
Body Diode Reverse Recovery Time
trr
Body Diode Reverse Recovery Charge
Reverse Recovery Fall Time
Qrr
ta
IF = 10 A, dI/dt = 100 A/µs, TJ = 25 °C
Reverse Recovery Rise Time
tb
Notes:
a. Pulse test; pulse width ≤ 300 µs, duty cycle ≤ 2 %.
b. Guaranteed by design, not subject to production testing.
Min.
30
1.2
20
0.3
Typ.
Max.
0.035
3.5
2.5
± 100
0.2
35
0.0092
0.0115
38
0.0115
0.0145
1790
310
130
30
45
13.7
21
5
4
1.2
2.4
23
45
13
25
29
55
12
24
11
22
10
20
22
45
8
16
5.6
50
0.53
0.7
17
30
5.5
10
8
9
Unit
V
nA
mA
A
Ω
S
pF
nC
Ω
ns
A
V
ns
nC
ns